GMP- compliant formulation and quality control of sodium [124I]iodide for oral applications
Year: 2025
Type: article
Abstract: • Development of an efficient and convenient procedure for the oral applications of sodium [ 124 I]iodide using a solid sugar matrix • Development of the GMP-compliant [ 124 I]sodium iodide quality control procedure based on international guidelines • Successful application in the PET diagnosis of more than 500 cancer patients
Source: Applied Radiation and Isotopes
Authors: M. Nader, D. Kersting, K. Herrmann, F.A. Al Shaikhli, F. Zarrad, J. Schmitz, K. Sharifi Haghighat
Institution: Essen University Hospital
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: hybrid
Estimated APC paid: $3,220