Work

Hybrid reluctance-actuated Stewart platform for high-precision position control

Year: 2025
Type: article
Abstract: This paper presents a Stewart platform with hybrid reluctance-actuated struts to achieve six-degrees-of-freedom motion capability. Tailored hybrid reluctance actuators (HRAs) are integrated into a novel strut design to achieve axial force transmission to the Stewart platform’s end effector via flexure-based joints. Each actuator has a motion range of ± 1 mm, leading to a platform workspace of ± 1.34 mm along the vertical z-axis and ± 1.1 mm in x- and y-direction. The rotational range amounts to ± 0.66 ∘ / 0.78 ∘ for tip/tilt motion. By implementation of a MIMO decoupling approach using canonical polyadic decomposition (CPD), position control bandwidths of up to 30 Hz are reached in the task space. The platform achieves millimeter stroke with sub-micrometer translational resolution (45 nm RMS), sub-microradian angular resolution (300 nrad RMS) and a bidirectional repeatability (1 σ ) of 0.15–0.32 µm and 3.5–4.8 µrad. The overall positioning accuracy (RMSE), quantified against external interferometric measurements, amounts to 1-2.3 µm in translation and 11–15 µrad in rotation.
Institution: TU Wien
Language: English
Open Access status: hybrid
Estimated APC paid: $3,340
OpenAlex ID: W4416423434
FWCI: 1.176
Cites: 28
Cited by: 3
Related to: