Development of a metabolic syndrome prediction model using smartphone-derived digital anthropometry
Year: 2025
Type: article
Study design: Observational Study
Abstract: Integrating metabolic syndrome (MetS) screening procedures into routine care remains challenging. Traditional anthropometric and body composition assessments, while useful, have drawbacks that limit their application. However, automated anthropometrics produced from smartphone scanning applications may offer a solution. This study aimed to determine whether smartphone-derived anthropometrics could effectively predict both MetS and its severity. A total of 281 participants underwent a MetS screening assessment to determine fasting blood pressure, lipids, glucose and waist circumference and completed a smartphone scanning assessment (MeThreeSixty ® ) to collect digital anthropometrics. Actual MetS classification and MetS severity (MetS index ), a continuous estimate of MetS progression, were determined using MetS screening data. Then, least absolute shrinkage and selection operator regression was used to develop a new MetS index prediction equation in a subset of participants ( n 226), which was subsequently tested in the remaining participants ( n 55), and MetS classification was predicted from the retained variables using logistic regression. The following equation was produced: Smartphone-predicted MetS index : −0·8880 + 0·1493( medication use = 1; 0 = no medication use ) + 0·0089( weight ) + 0·0079( bust circumf. ) + 0·0140 ( thigh circumf. ) – 0·6247( appendage-to-trunk circumf. index ), where medication use includes medications for hypertension, dyslipidaemia or hyperglycaemia. The newly developed MetS index prediction model demonstrated equivalence with actual MetS index and revealed acceptable agreement (R 2 :0·72; root mean squared error: 0·42; se of the estimate: 0·22) when evaluated in the testing sample ( n 55), although proportional bias was observed ( P < 0·001). Smartphone-predicted MetS classification demonstrated acceptable diagnostic performance with an accuracy of 92·7 % and an AUC of 0·89. Smartphone scanning applications can accurately assess MetS prevalence and severity, presenting new possibilities for health screening beyond clinical environments.
Source: British Journal Of Nutrition
Authors: Caleb F. Brandner, Grant M. Tinsley, Abby T. Compton, Sydney H. Swafford, Molly F. Johnson, Maria G. Kaylor, Hunter Haynes, Jon Stavres, Austin J. Graybeal
Language: English
Subfield: Physiology
Field: Medicine
Domain: Health Sciences
Open Access status: hybrid
Estimated APC paid: $3,550
Awards: G1422855837, G5020330245, G9000032014
OpenAlex ID: W4416454608
FWCI:
Cites:
Cited by:
Related to:
