Concomitant Surgical Ablation Using a Novel Bipolar Radiofrequency Clamp: Outcomes from the TRAC-AF Registry
Year: 2025
Type: article
Study design: Observational Study
Abstract: Background/Objectives: Surgical ablation for atrial fibrillation (AF) during cardiac surgery decreases perioperative morbidity and mortality and improves long-term patient outcomes. Because of these benefits, it has been designated a Class I surgical society recommendation. As surgical ablation techniques have evolved, so too have ablation tools such as radiofrequency and cryothermal devices. In this study, we evaluated real-world evidence (RWE) of concomitant surgical ablation featuring an epicardial left atrial encircling lesion created by a novel bipolar radiofrequency clamp. Methods: Thirteen centers in the observational Tracking Results of Ablation to Combat AF (TRAC-AF) Registry (NCT05111015) contributed data used in this analysis. Included patients had AF and received the epicardial encircling lesion during cardiac surgery. Additional ablation and follow-up were per institutional standard of care. Freedom from AF/atrial tachycardia (AT)/atrial flutter (AFL) and survival were evaluated using the Kaplan–Meier method. Safety was evaluated within 30 days of the procedure. Results: Among 327 patients, 70% were male with a median age of 69 years. Sixty-nine percent had paroxysmal AF. Median left atrial diameter was 4.1 cm, and CHA2DS2-VASc score was 3. Isolated coronary artery bypass graft and aortic valve surgery were performed in 51% and 11% of patients, respectively. One- and two-year survival rates were 95.3% (95% CI, 91.7–97.3%) and 88.1% (95% CI, 81.5–92.5%). Through 12- and 24-months freedom from AF/AT/AFL was 87.4% (95% CI, 81.3–91.6%) and 79.9% (95% CI 72.0–85.8%). Mortality within 30 days of the index procedure was 1.5%. No serious adverse events were related to the epicardial cardiac ablation procedure or device. Conclusions: RWE from the TRAC-AF Registry demonstrates surgical ablation including an epicardial left atrial encircling lesion made by a novel bipolar RF clamp was safe and resulted in favorable long-term rhythm outcomes.
Source: Journal of Clinical Medicine
DOI: 10.3390/jcm14238360
Authors: Christian Shults, Armin Kiankhooy, Shaf B. Holden, Hetal D. Patel, Frans van Wagenberg, Gansevoort H. Dunnington, Andres Samayoa, Theodore Wright, Andrew J. Sherman, Eric Sievers, Aaron Kime, Jeffrey Newman, Andrew Barksdale, Joshua N. Baugh, Yasir Abu-Omar, Gregory Rushing, Marc Gerdisch
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $3,137
Funder: AtriCure
OpenAlex ID: W4416665113
