Sutureless Aortic Valve Replacement with Annular Plication Technique in an Oversized Annulus

Year: 2025
Type: article
Study design: Case Report
Abstract: We present the case of a 72-year-old man with symptomatic severe aortic regurgitation and moderate aortic stenosis, and an annular diameter of 30 mm, exceeding the recommended range for sutureless Perceval valve implantation. To reduce the annular size to allow implantation of the Perceval XL valve, an annular plication technique was employed, involving three horizontal mattress sutures placed at the interleaflet triangles. A totally endoscopic approach via right mini-thoracotomy was utilized. Postoperative echocardiography confirmed excellent valve positioning and no paravalvular leak. The patient recovered uneventfully and remained asymptomatic with good prosthesis function at the 3-year follow-up. This case demonstrated that annular plication enables the safe use of the Perceval valve in patients with a mildly oversized annulus and may expand its applicability in minimally invasive settings.