Repeatability of Rapid Human Cardiac Phosphorus MRSI ( 31 P ‐ MRSI ) Using Concentric Ring Trajectory Readouts at 7 T
Year: 2025
Type: article
Abstract: PURPOSE: PCr/ATP ratio is determined at 7 T typically using Fourier-transform based magnetic resonance spectroscopic imaging sequences (FT-MRSI). These sequences require acquisition times longer than desirable for inclusion in cardiac clinical trials. Concentric ring trajectory (CRT-MRSI) has been described as an accelerated alternative k-space sampling method. In this work we aim to establish the inter- and intra-session repeatability of three different CRT protocols and compare their voxel-based PCr/ATP ratios to compartment-based PCr/ATP values extracted with spectroscopy using a linear algebraic model (SLAM) method. METHODS: Seven healthy volunteers were scanned twice on two different days. Each time a 6.5-min 3D FT-MRSI acquisition with 10 × 10 × 10 resolution was followed by a 2.5-min CRT-MRSI with matched resolution, a 1.5-min CRT-MRSI with matched resolution, and a 6.9-min CRT-MRSI with 12 × 12 × 12 resolution. Spectra from a mid-septal voxel and the cardiac compartment were fitted with the OXSA toolbox. PCr/ATP ratio was quantified for inter- and intra-session repeatability analysis. RESULTS: Paired repeated measurements were not significantly different within subjects. Good inter- and intra-session agreement was observed between FT-MRSI and each CRT-MRSI protocol. CRT-MRSI protocols all had larger coefficients of repeatability (CoR) than FT-MRSI. CRT-SLAM-based PCr/ATP values had lower CoR than voxel-based data except for 2.5-min CRT-SLAM, and high-resolution CRT-SLAM had lower inter-session CoR compared to FT-MRSI (1.42 vs. 2.21). CONCLUSION: P MRS acquisition times and the use of more advanced energetics-probing techniques in clinical studies.
Source: Magnetic Resonance in Medicine
DOI: 10.1002/mrm.70220
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: hybrid
Estimated APC paid: $3,680
Funders: Wellcome Trust, National Institute for Health and Care Research, Department of Health and Social Care, Austrian Science Fund, Novo Nordisk, Agentúra na Podporu Výskumu a Vývoja, Vedecká Grantová Agentúra MŠVVaŠ SR a SAV, Novo Nordisk Fonden, Directorate for Biological Sciences, Biotechnology and Biological Sciences Research Council, NIHR Oxford Biomedical Research Centre, NIHR Cambridge Biomedical Research Centre
Awards: G128649688, Wellcome Centre for Integrative Neuroimaging, G2493601830, G2537968379, G2792775314, State-of-the-Art Ultra-High-Field MRI for Crossing Scales in Basic Neuroscience, Developing spatially resolved imaging of functional neurochemistry and cell- type specific microstructure in the living human brain, Výskum vlastností magnetických nanočastíc pre účely zobrazovania v biomedicínskej diagnostike na báze metód magnetickej rezonancie., G5219700674, G5230424598, Imaging dynamics of glioma metabolism via MRI, G5495543251, G6248927271, Wellcome Centre for Integrative Neuroimaging, Novel multi-nuclear magnetic resonance spectroscopy approaches for the sensitive and robust assessment of human cardiac energetics, Wellcome Centre for Integrative Neuroimaging - extension
OpenAlex ID: W4417144313