Discrepancy between international normalized ratio measurements in a heterozygous carrier of F10:p.Gly244Arg with recurrent venous thromboembolism: a case report
Year: 2025
Type: article
Study design: Case Report
Abstract: Background: affect INR measured with thromboplastins from different species. Key Clinical Question: :p.Gly244Arg heterozygosity affects the INR when measured using rabbit compared with human thromboplastin? Clinical Approach: :p.Gly244Arg. Conclusion: to ensure sufficient anticoagulant VKA treatment.
Institution: Næstved Sygehus
Language: English
Subfield: Hematology
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $2,250