Work

Beam Based Monitoring of the Rf Photo Gun Stability at Pitz

Year: 2010
Type: conference-paper
Abstract: The stability of the photo injector is a key issue for the successful operation of linac based free electron lasers. Several types of jitter can impact the stability of a laser driven RF gun. Fluctuations of the RF launch phase and the cathode laser energy have significant influence on the performance of a high brightness electron source. Bunch charge measurements are used to monitor the stability of the RF gun phase and the cathode laser energy. A basic measurement is the so called phase scan: the accelerated charge downstream of the gun is measured as a function of the launch phase, the relative phase of the laser pulses with respect to the RF. We describe a method which provides simultaneous information on RMS jitters from phase scans at different cathode laser energies. Fluctuations of the RF gun phase together with cathode laser energy jitter have been measured at the Photo Injector test facility at DESY in Zeuthen (PITZ). Obtained results will be presented in comparison with direct independent measurements of corresponding instability factors. Dedicated beam dynamics simulations have been done in order to optimize the method performance.
Language: English
Open Access status: green
OpenAlex ID: W45511185
FWCI: 1.349
Cites: 2
Cited by: 4
Related to: 10