Work

Description and initial operating performance of the Langley 6-inch expansion tube using heated helium driver gas

Year: 1975
Type: article
Abstract: A general description of the Langley 6-inch expansion tube is presented along with discussion of the basic components, internal resistance heater, arc-discharge assemblies, instrumentation, and operating procedure. Preliminary results using unheated and resistance-heated helium as the driver gas are presented. The driver-gas pressure ranged from approximately 17 to 59 MPa and its temperature ranged from 300 to 510 K. Interface velocities of approximately 3.8 to 6.7 km/sec were generated between the test gas and the acceleration gas using air as the test gas and helium as the acceleration gas. Test flow quality and comparison of measured and predicted expansion-tube flow quantities are discussed.
Author: J. Moore
Language: English
Open Access status: green
OpenAlex ID: W52896216
FWCI: 5.382
Cites: 11
Cited by: 17
Related to: 10