Abstract: Microgrooved or microfin tubing is commonly used in refrigeration and air conditioning products because of the greatly enhance heat transfer coefficients it provides.This paper presents some results of visualization of horizontal two-phase air-water flow in clear tubing with internal grooves.Tubes of 15.2 mm inner diameter were prepared with twenty axial or helical (9 and 18 degree) grooves to allow for visualization between the grooves.Time averaged liquid film thickness and local thin film particle image velocimetry (PIV) data were obtained.These results indicate that grooves act to redistribute and thin the liquid film on the tube wall which would lead to increased heat transfer coefficients.In addition, the 18 degree helix generates the thinnest average film thicknesses in agreement with heat transfer coefficient measurements in these tubes.