Work

Integrating electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) in epilepsy.

Year: 2010
Type: dissertation
Abstract: Introduction Combined electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) studies enables to non invasively investigate human brain function and to find the direct correlation of these two important measures of brain activity. The combination of these technologies provides informations and details on the spatio-temporal aspects of human brain processing. fMRI has an excellent spatial resolution and allows the localization of brain regions in which there is a change in the level of neuronal activity during an experimental condition compared to a control condition. In contrast, EEG measures neuronal currents directly from the subject’s scalp with a high temporal resolution in the range of milliseconds. Combined recording wants to overcome the spatial limitations of EEG and the temporal limitations of fMRI, using their complementary features. For instance, combined EEG-fMRI technique can be used to identify the neural correlates of clinically or behaviourally important spontaneous EEG activity, such as interictal spikes, the alpha rhythm and sleep waves. The presurgical evaluation of patients with epilepsy is one of the areas where combining EEG and fMRI has considerable clinical relevance for localizing the brain regions generating interictal epileptiform activity. fMRI is mostly used in the study of sensory, motor and cognitive functions, where there is a difference between experimental condition and control condition. In the context of epilepsy, one can consider the control condition to occur when the EEG is at baseline and experimental condition to correspond to the presence of an epileptic discharge. The conventional analysis of EEG-fMRI data is based on the visual identification of the interictal epileptiform discharges (IEDs) on scalp EEG which are used in conjunction with a General Linear Model (GLM) approach to analyze fMRI data. A model is obtained by the convolution of the EEG events, which are represented as stick functions of unitary amplitude, with a model of the event-related fMRI response, represents by the haemodynamic response function (HRF); maps showing regions of significant IED-related change are obtained through voxel-wise fitting of the model and application of appropriate statistical thresholds. In this thesis we present an easy to use approach for combined EEG-fMRI analysis developed to improve the identification of the IEDs. The novel automatic method is based on Independent Component Analysis (ICA) and allows to detect IED activity in order to use it as a parametric modulator in fMRI analysis. The Novel Method Data quality is a crucial issue in multimodal functional imaging and data integration. Both fMRI and EEG data acquisition processes can severely affect the other’s performance through electromagnetic interactions, therefore the pre-processing is necessary for both EEG and fMRI data. While for fMRI data the pre-processing is generally standard, apart from the choice of spatial smoothing; the EEG pre-processing requires a complex and not one-way procedure to remove the artifacts. In literature different methods have been developed to remove gradient and pulse artifacts, considering both hardware and software solutions. The gradient EEG artifact removal method implemented in our EEG system acquisition did not give completely satisfactory results; so we decided to developed a novel method. Since the project regarding the gradient filter started together with the novel EEG-fMRI integration method and the analysis on patients with partial epilepsy are still in progress to avoid the introduction of a further variable in the validation of the method we decided to use the algorithms implemented in the SystemPlus software. After a pre-processing applied on EEG data and composed by a re-reference and filtering, a method based on ICA decomposition was applied. In the field of biomedical signal processing, Blind Source Separation (BSS) methods are generally used to separate multi-channel recordings into their constituent components; ICA is a subset of such techniques used to separate statistically independent components from a mixture of data. ICA decomposition of the data was performed using FastICA algorithm implemented in EEGLAB. The novel method consists in four fundamental steps: • Selection of components • Reconstruction of EEG signal • Selection of channel and FFT analysis • Construction of EEG regressor The crucial point is the selection of components. To select the components related to IED activity, we used a time-frequency representation obtained by using wavelet-based analysis. We computed the wavelet power for all the components in the epochs of interest and then, for each component, we selected from the frequency bins the one with the maximal power over total recording session. Finally power was averaged along time, obtaining one value for each component. Components that exceeded mean value ± standard deviation were chosen for further analysis. After the components of interest have been selected, they were back projected to obtain a new EEG signal (reconstructed EEG). A Fast Fourier Transform (FFT) analysis was applied on the time series of the selected channel (where the IED activity is clearly visible) for epochs acquired during each fMRI volume. Then the power time course created for all volumes was used to form the EEG regressor used in GLM analysis. Discussion The aim of the research project here described is the development of an innovative procedure for integrating neurophysiological and functional neuroimaging data. In fMRI processing the selection of the experimental paradigm as difference between task and rest conditions is of great importance, in fact the information related to the experimental events and to the rest condition are to be used as input in GLM analysis. Regressors of interest are typically obtained by convolving impulses or boxcar functions, which are representations of the events or conditions of interest, with a model of the BOLD response (HRF). In the study of spontaneous EEG activity without a task condition we can use the EEG signal to derive the input for GLM. In literature several methods for the analysis of simultaneous acquired EEG-fMRI data are proposed. The aim is to find regions of BOLD change linked to the discharges. In the conventional approach each event is marked by visual inspection of the EEG data recorded in the scanner, then a series of identical impulses functions (delta functions) are created and convolved with a canonical HRF, obtaining the regressor for a GLM. The methods presented in Formaggio et al., 2008 and Manganotti et al., 2008 are two attempts of EEG and fMRI integration. However in the first study signals were recorded simultaneous but their correlation analysis was as whether they were recorded in separate sessions, while in the second one we used a conventional approach based on the creation of the regressor as a set of stick functions representing the timing of IED activity. Hence the necessity to developed a new method of integration. The new method aimed to improve upon existing methods since the epileptiform activity, recorded from a scalp EEG, is used to modulate changes in BOLD signal. ICA decomposition is used to identify signals representing activity of interest but one of the major difficulties is their identification. We proposed an automatic selection based on wavelet analysis, because typically IEDs activity is higher in amplitude than background activity and its power increases. The reconstructed EEG signal is obtained with the only contribution of the selected components, method used in many studies to remove artifact from EEG traces. Like in the resting state studies, where alpha rhythm or its spectrum is used as a regressor in GLM analysis, the power time series of EEG signal is used as GLM input. Using conventional approach each event is treated as equal, although epileptic spikes may vary in amplitude, duration and also in appearance. They ignore the fact that IED activity is continuous and contains also fluctuating subthreshold epileptic activity, not clearly seen on surface EEG recordings. In contrast, such meaningful information is contained in the ICA factors employed in our method. Analysis of in silico data validates the method, since demonstrates the reliability of reconstructed IED regressor. All five patients with partial epilepsy we enrolled in this study had frequent interictal focal slow wave activity on routine EEG. In all continuous EEG-fMRI recording sessions, after fMRI artifact removal, we obtained a good quality EEG that allowed us to detect spontaneous IEDs and analyze the related BOLD activation. In their focal distribution, these BOLD activations resembled the focal IEDs seen on routine scalp EEG and EEG recorded during EEG-fMRI sessions; and they are in agreement with the clinical history of the patients. We plan to increase the number of patients and also test this method on EEG with various patterns other than the epileptiform discharges, for example in resting state analysis where, like in the context of epilepsy, the activation task used to drive GLM analysis is missing. For this reason EEG signal is necessary to evaluate hemodynamic changes in fMRI and its analysis is fundamental to derive informations on the electrical activity. Even if it is believed that the HRF to epileptic spikes does not vary significantly from that to external stimuli, HRF could shows different peak times or even non canonical shape in the epileptogenic zone. This observation may be advanced as a working hypothesis for further investigating the choice of HRF in patients with epilepsy; future developments possibly involve a study of BOLD signal in this category of patients, and its relation with the electrical activity. In this way the sensitivity of EEG-fMRI studies in epilepsy could be improved with the use of different HRFs. Moreover, in the future, we will test the inte
Language: English
Field: Medicine
Open Access status: green
OpenAlex ID: W540812
Cites:
Cited by: 1
Related to: 10