Work

Simulations of ITER Plasma Limiter Start-Up Conditions

Year: 2006
Type: conference-paper
Abstract: 1. Introduction. Analysis of the current ramp-up phase of plasma discharges in ITER is an important part of the design. Among other things, good accuracy is required to determine the fraction of power flowing to the plasma boundary and intercepted by the start-up limiter(s), and the resulting heat flux distribution, throughout the limiter phase of the discharge, for all anticipated limiter start-up scenarios. This paper summarizes the results of a recent modeling effort conducted with the plasma transport code ASTRA to simulate typical limiter start-up sequences proposed for ITER. 2. Transport model. This study was conducted by using the plasma transport code ASTRA [1] which is a 1.5-dimensional time dependent simulation code that comprises of a system of 1-D diffusion equations for densities and temperatures of ions and electrons, a 2-D equilibrium equation, and, a variety of other modules to describe additional heating, current drive and other non-diffusive processes in tokamak plasmas. The heat transport of electrons and ions is evaluated assuming that the properties of the plasma confinement during the current ramp-up are close to those during the steady state ohmic discharges. Several calibration runs were performed by using either one of the Ohmic
Language: English
Open Access status: green
OpenAlex ID: W5441483
FWCI:
Cites: 2
Cited by:
Related to: 9