Comparison of flow patterns around stenotic area in elastic PVA-H model and in rigid-like silicone model
Year: 2013
Type: conference-paper
Abstract: Vascular stenosis reduces the volume of blood flow, resulting in embolism, or rupture of blood vessels [1]. Plaques exhibit a wide range of stiffness [2], and stiffness is an important factor in plaque behavior [3]. Moreover, plaque is a sign of high-risk plaque vulnerability, leading rupture of the fibrous cap associated with the release of thrombogenic factors into the arterial lumen, and resulting in repeated ischemic stroke during a short interval after diagnosis [4]. The changes in the blood flow conditions associated with types of soft plaque are often in contrast to the changes associated with calcified plaque, which is a type of hard plaque and is immobile. Blood flow conditions are attractive features for the advancement of diagnostic techniques for detecting stenoses or plaques. Many studies have been performed focusing on stenotic flow conditions using rigid tubes to represent blood vessels [5, 6]. These studies report that the geometry of the stenosis is an important factor influencing blood flow conditions. However, few studies have investigated the effect of the soft plaques on the blood flow behavior. In this study, the effect of the plaque and blood vessel deformation on blood flow conditions has been evaluated using in vitro studies. Stenosis severity (SS) is an important factor for diagnosis. Hence, we measured SS under various pressure levels. Flow velocity measurement is also important because a peak systole velosity greater than 200 cm/s in internal carotid artery (ICA) is one of the most reliable predictors of an ICA SS of greater than 70% [7]. Wall shear stress (WSS) is one of the risk factors for vessel diseases [8, 9], and the WSS is strongly affected by eddies in the recirculation area [10]. Reattachment point (RAP) can be one index for determining the size of the eddies. Thus, we located the RAP instead of WSS because the former can be more easily identified in the images of flow distributions using PIV measurement in this in vitro study. A biomodel with varying plaque stiffness is useful for measuring SS, WSS, and RAP. To represent an in vivo condition, a poly (vinyl alcohol) hydrogel (PVA-H) biomodel imitating the mechanical properties in the human body has been introduced instead of a silicone biomodel [11]. Owing to its transparency [12], PVA-H is beneficial for observing flow using PIV method [13]. A PVA-H stenosis model has been developed. Shimizu et al. developed the model with varying stiffness [14]. Ji et al. developed another PVA-H stenosis model to demonstrate plaque deformation with pulsatile flow [15]. They reported that variation in the flow rate caused the deformation. They proposed that plaque stiffness is an important parameter associated with deformation of blood vessels and plaques themselves. Thus, it is considered that flow pattern in blood vessels can be changed by vessel and plaque deformations. Furthermore, observations of flow conditions using a PVAH stenosis model may provide better understanding of vessel diseases because flow pattern and deformation of the model can be simultaneously observed with the PIV method. The purpose of this study is to determine differences in flow conditions between the silicone and PVA-H models in order to discuss experimental materials for arterial wall and flow observations. In particularly, the relationship between the deformation of the vessel after the stenosis and RAP change was observed in this paper. In combination with our previous paper [16], such information helps to establish a relationship between blood flow conditions and disease progression.
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W565473932