Work

Multivariate Evaluation of Indoor Air Quality, Building Characteristics and SBS Complaints

Year: 2003
Type: conference-paper
Abstract: The multi-criteria decision-making procedures, PROMETHEE (Preference Ranking Organisation Method for Enrichment Evaluation) and GAIA (Geometrical Analysis for Interactive Aid), factor analysis (Varimax rotation), Fussy Clustering and Partial Least Squares (PLS) have been applied to indoor air quality data.PROMETHEE ranked the buildings on the basis air quality influencing criteria such as building characteristics, indoor levels of volatile organic compounds, polycyclic aromatic hydrocarbons, fungi, bacteria, submicrometre and supermicrometre particles.GAIA and factor analysis evaluated the relationships between building characteristics and air quality.The results showed that the indoor air qualities of the residential houses, offices and hair dressing saloons were strongly dependent on their building designs, distances of the buildings from vehicular emission sources, indoor activities and presence of in-built garages.However, association between indoor air quality and the age of a building was weak as was the association between air quality and Sick Building Syndrome (SBS) complaints.Striking similarities in the results obtained by the different multivariate procedures highlight the potential of such techniques for ranking information, source apportionment and development of control strategies for indoor air pollution.
Language: English
Open Access status: green
OpenAlex ID: W57521520
FWCI: 4.629
Cites: 8
Cited by: 1
Related to: 10