Work

High temperature, high pressure gas loop - the Component Flow Test Loop (CFTL)

Year: 1984
Type: article
Abstract: The high-pressure, high-temperature, gas-circulating Component Flow Test Loop located at Oak Ridge National Laboratory was designed and constructed utilizing Section III of the ASME Boiler and Pressure Vessel Code. The quality assurance program for operating and testing is also based on applicable ASME standards. Power to a total of 5 MW is available to the test section, and an air-cooled heat exchanger rated at 4.4 MW serves as heat sink. The three gas-bearing, completely enclosed gas circulators provide a maximum flow of 0.47 m/sup 3//s at pressures to 10.7 MPa. The control system allows for fast transients in pressure, power, temperature, and flow; it also supports prolonged unattended steady-state operation. The data acquisition system can access and process 10,000 data points per second. High-temperature gas-cooled reactor components are being tested.
Language: English
Field: Energy
Open Access status: green
OpenAlex ID: W58520392
FWCI: 2.648
Cites: 6
Cited by: 2
Related to: 10