Demonstration of an optical parametric oscillator system at 1.57 mü for integrated path differential absorption lidar measurements of carbon dioxide
Year: 2006
Type: conference-paper
Abstract: In order to measure the concentration of atmospheric carbon dioxide an Integrated Path Differential Absorption (IPDA) lidar is developed based on an optical parametric oscillator (OPO) using potassium titanyl phosphate (KTP) in noncritically phasematched configuration.The tuning range of this device was found to match favorably to CO2 absorption lines showing adequate absorption cross-section with low temperature and pressure sensitivity.The spectral properties of the OPO were investigated in detail.A prerequisite for meaningful CO2 measurements is a high precision of the lidar system.Therefore, first error analyses have been performed on an experimental basis in addition to CO2 column measurements showing the potential of the system.
Source: elib (German Aerospace Center)
Language: English
Subfield: Spectroscopy
Field: Chemistry
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W60197915