Work

TMX-U neutral pressure measurement diagnostic systems

Year: 1984
Type: conference-paper
Abstract: The Tandem Mirror Experiment-Upgrade (TMX-U) has a large and complex system of Baird Alpert, magnetron, and Penning gauges, in addition to mass spectrometers (RGA), all of which measure neutral pressures in the many internal regions of TMX-U. These pressure measurements are used as part of the confinement physics data base as well as for management of the TMX-U vacuum system. Dynamic pressures are modeled by a coupled-volumes simulation code, which includes wall reflus, getter pumping, and plasma pumping.
Language: English
Open Access status: green
OpenAlex ID: W61278097
FWCI:
Cites: 2
Cited by: