Work

Levitation Experiment Using a High-Temperature Superconductor Coil for a Plasma Confinement Device

Year: 2001
Type: article
Abstract: Levitation experiments using a high-temperature superconductor coil have been carried out. A coil with a minor radius of 42 mm was fabricated with a Bi-2223 tape conductor, and immersed in the liquid nitrogen. The coil current was induced by the field-cooling method up to the critical current value. The current decay of the coil can be accounted for by the flux flow resistance and the normal resistance at the lap joint. The high-temperature superconductor coil can be levitated for 4 min or more within an accuracy of 25–30 µm.
Language: English
Open Access status: bronze
OpenAlex ID: W2020186347
FWCI: 3.375
Cites: 5
Cited by: 20
Related to: 9