Brandteknisk dimensionering av oskyddade träförband : En jämförelse mellan Eurocode 5 och alternativa metoder

Year: 2013
Type: dissertation
Abstract: Fire design of wooden building components is based on requirements for load capacity for a specified period. For this case in Sweden design rules according to Eurocode 5 applies. Unprotected connectors are considered weak point when being a part of members in buildings when designing for fire resistance. The aim of this work was to identify, clarify and illustrate how such a fire safety design is performed, in particular according to the applying standards of Eurocode 5 but also from alternative methods presented in a report (FSITB) published by SP Trä, from a European research project in 2010. The goal was to, through literature studies and analysis, identify differences and influences between methods.A theoretical experiment, by implementation on two representative examples, was performed to concretize the results of the study. The study has been restricted to unprotected timber connectors and the implementation examples concern only connectors with slotted-in steel plates. The results have shown that the fire safety design of unprotected connections, is performed either by reduction of the resistance with so called reduction factor method, or by offsetting the expected char depth with additional dimensions, called cross section compensation. Nominal and alternative methods differ primarily by which time of the mathematical relationships are valid, but also by the size of the reduction factor, due to different values of a specific factor. It has been shown that alternative methods introduce more favorable values of the reduction factor, but also longer valid times for the same. Alternative methods, however, offer no opportunity to verify the resulting fire resistance times and mathematical relationships. For the special case with two or three slotted-in steel plates a very favorable method was presented, based on the corresponding effective area. The outcome questions the carrying capacity for wood connectors at normal temperature according to Eurocode 5. Although the cross section from expected char depth is compensated with relatively small dimensions, the differences affect the element mainly due to fixed dimension ranges from glulam suppliers. This can make the fitting of the elements as difficult as getting appropriate dimensions available from suppliers.v Förord Detta examensarbete har genomförts under sjätte och sista terminen på Byggingenjörsprogrammet vid Mittuniversitetet. Brandteknisk dimensionering brukar normalt betraktas som ett fristående ämnesområde och har därför enbart nämnts mycket kort under ordinarie kurser på utbildningsprogrammet. Min önskan och förhoppning med detta arbete har därför varit att kunna presentera en överskådlig bild över hur detta ämne hanteras för trä och i synnerhet oskyddade träförband. Jag hade önskat åstadkomma en komplett struktur för sådant dimensioneringsarbete, men har under arbetets gång fått inse att detta inte är praktiskt möjligt p.g.a.bränders komplexitet. Jag har därför valt att betrakta denna rapport som ett lämpligt underlag att utgå från och vid tillämpning hänvisas givetvis till gällande normer för varje specifikt fall. Jag vill rikta ett stort tack till alla som hjälpt mig, dels att genomföra detta arbete men också för stöttning allmänt i mina studier genom hela min studietid på Byggingenjörsprogrammet. Samtliga har uppmuntrat mig kontinuerligt. Jag vill därför rikta min tacksamhet till intern handledare på institutionen för svar på många frågor inom konstruktion, min externa handledare för många intressanta diskussioner av frågeställningar som kan uppstå i konstruktionsarbete och slutligen examinatorn, för stöd med utformning och innehåll av denna rapport.
Language: Swedish
Open Access status: green
OpenAlex ID: W644482397
Cites: 1
Cited by:
Related to: 10