Year: 1990
Type: article
Abstract: Shipping casks, after being submerged in spent fuel pools for the purpose of loading or unloading fuel, resist complete removal of the adsorbed contamination. To systematically study the mechanisms involved, 122 metal surface samples were immersed in the spent fuel storage pool of the Callaway Power Plant for periods of 7 to 30 days. After being removed from the pool, all samples were washed and wiped (with cloth) using demineralized water. They were then gamma counted for absolute activity, by using Eu-152 as an energy efficiency calibrator, applied uniformly to unexposed sample surfaces. Swipes were taken after each of 3 days of such environmental conditioning. Following this conditioning, selected samples were again counted to determine absolute contamination remaining on the samples. 2 refs., 1 tab.
Authors: K. Reaves, J.F. Kunze, Lu Kang, P.C. Bennett
Language: English
Subfield: Safety, Risk, Reliability and Quality
Field: Engineering
Domain: Physical Sciences
Open Access status: green