Microbial Counts and Microbial Patterns in the Operation Room of Dr. Drs. M. Hatta Brain Hospital, Bukittinggi.

Year: 2025
Type: article
Abstract: The microbiological quality of room air is an environmental factor that influences the spread of nosocomial infectious diseases in hospitals due to transmission mechanisms. The purpose of the study was to determine the type of germs and the number of germs in the air, walls, and floors in the operating room of the Central Surgical Intalasi Hospital DR. drs. M. Hatta Bukittinggi Hospital. 'Study of Air Germ Numbers, Floor Swabs, and Wall Swabs at the Brain Hospital DR. Drs. M. Hatta Bukittinggi.' yields conclusions. Before use, operating room 1 averaged 19.7 °C. The hospital operating room temperature must meet Permenkes No. 1204/Menkes/SK/X/2004's 19-24 °C range. Before use, operating room 1 averaged 25.52% RH. The Central Surgical Installation (IBS) Brain Hospital DR. Drs. M. Hatta Bukittinggi's operating room instruments and personnel's bodies, hands, and clothing were found to be contaminated with Bacillus subtilis, Staphylococcus albus, and Streptococcus sp.