Report on quality control performed on 188W/188Re for use in radiolabelling studies
Year: 2024
Type: article
Abstract: SECURE Project Deliverable D3.8 EXECUTIVE SUMMARYThis deliverable aims to verify the quality of the Re-188 solution eluted from the R&D 188W/188Re generator (SCK CEN). Results of comparative QC tests of Re-188 eluate performed at NCBJ and UMCL are presented. The tested parameters include radioactivity, identification, radionuclidic purity, chemical purity, radiochemical purity, aluminum content, pH, and results of Re-188 radiolabelling with DMSA using in-house developed dry kit for Re-188 labelling.Funded by the European Union. Views and opinions expressed are however those of the author(s) only and do not necessarily reflect those of the European Union or the European Commission. Neither the European Union nor the European Commission can be held responsible for them.
Authors: Cieszykowska, Izabela, Miko!ajczak, Renata, Kolenc, Petra, Elema, Dennis
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: green
Funder: European Commission
OpenAlex ID: W6912203216
FWCI:
Cites:
Cited by:
Related to: