Research and Application of Corrosion and Scaling Prevention Strategies for Long-Distance Heating Pipe Network with Large Temperature Difference
Year: 2024
Type: article
Abstract: Ningxia A Heat Supply Company adopted the large temperature difference long-distance heating technology.During two consecutive heating seasons from 2019 to 2021, significant scaling, pitting corrosion of stainless steel and corrosion of carbon steel were observed in the secondary pipeline network, which severely impacted the heating effect for residents during the winter.The heat supply company conducted research and development on scale and corrosion inhibitors,as well as studies on the critical conditions for pitting corrosion,based on the characteristics of its water quality and operating conditions.Ultimately, an anti-corrosion and anti-scaling strategy centered on the addition of TC-type scale and corrosion inhibitors was determined.Through industrial trials, random inspections of the heat exchanger plates revealed no significant pitting or scaling, and the results of carbon steel corrosion coupon tests indicated that the corrosion rate of the inner pipeline walls was effectively controlled.This ensured the safe and economical operation of the heating system.The corrosion and scale prevention strategy has shown great potential for broader application in the same type of heating systems.
Author: ZHENG Gang, LI Jingang, WANG Dingli, GONG Qingchen, XIAO Haigang, HUANG Wanqi
Institution: Thermal Power Research Institute
Language: English
Subfield: Materials Chemistry
Field: Materials Science
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W6943583787
FWCI:
Cites:
Cited by:
Related to: