Work

Assessment of Radiation Protection Status of the Radiology Departments of Two Selected Secondary Hospitals in Kano Metropolis, Kano State, Nigeria

Year: 2025
Type: article
Abstract: Background: During the operation of X-ray machines, radiology personnel and individuals in adjacent areas may inadvertently be exposed to harmful doses of ionizing radiation. Objective: This study examines the levels of secondary radiation in two busy radiology departments of secondary health facilities in Kano metropolis. Methods: Radiation doses were measured using a Radiation Alert Ranger MultiPurpose Digital Survey Meter at various locations by taken first the background radiation, including the control panel, changing room, patient waiting area, protected cubicle, dark room/digitizer, and radiographer’s office. Results: The highest measurement was 22.653 μSv/h in the changing room at Hospital 'B', and the lowest was 0.011 μSv/h in the patient waiting area at Hospital 'A'. Background radiation levels ranged from 0.077 to 0.203 μSv/h, with the highest levels recorded in the CT unit at Hospital 'B'. Conclusion: The study emphasizes the need for continuous monitoring and stringent control of radiation exposure to ensure the safety of medical staff and the general public.
Source: JRRS
Authors: Dambele, Musa Y., Wada, Abdullahi M., Mohammed, Abba, Ahmad, Umar F., Baba, Samaila A., Emmanuel, Richard I., Hassan, Mohammed, Chiegwu, Hyacinth U
Language: English
Field: Medicine
Open Access status: green
OpenAlex ID: W6959318404
FWCI:
Cites:
Cited by:
Related to: