Exploiting the use of a liquid waveguide capillary cell for spectrophotometric determinations in flow-based systems

Year: 2011
Type: dissertation
Abstract: In this thesis, the use of a liquid waveguide capillary cell (LWCC) was exploited for the spectrophotometric determination of several analytes in different types of water. With the purpose of in-line sample handling, different flow approaches were used for the development of simple, robust, cheap and automated analytical procedures. The first procedure was based on a sequential injection analysis (SIA) system for the determination of iron in coastal waters. With the goal of reaching low levels of iron, a LWCC was coupled to the system. This procedure used a doubled-line SIA system to improve mixing conditions between sample and reagents. The detection was based on a colorimetric reaction and two different reagents (ferrozine and 1,10-phenanthroline) were tested. The absorbance measurements were carried out at the wavelengths of 512 and 562 nm for the detection of iron-1,10-phenathroline and iron-ferrozine complex, respectively. An interference study was performed for both reagents. The developed method was also applied to natural waters (river, well, ground, potable and sea waters) and then compared with the reference procedure. One certified reference water sample was used to test the accuracy of the developed method. The objective of the second work was to determine iron at lower levels than the previous work and, as a consequence, to measure the levels of iron in ocean waters. With this in mind, a LWCC and a pre-concentration resin were coupled to a multisyringe flow injection analysis (MSFIA) system. Two different pre-concentration resins (Chelex 100 and NTA Superflow) were tested and evaluated. The determination of iron was also based on a colorimetric reaction and two reagents were tested, ferrozine and ammonium thiocyanate. The reactions were monitored at the wavelengths of 480 and 562 nm for the detection of iron-ammonium thiocyanate and iron-ferrozine complex, respectively. The accuracy was assessed using a certified reference water sample. A multi-parametric system for the spectrophotometric determination of zinc and copper at low levels in waters was the third work of this thesis. To attain this objective, a LWCC was coupled to a MSFIA system. The developed procedure for both analytes was based on a colorimetric reaction with zincon reagent at different pH values and monitored at 620 nm. Zincon reagent reacts only with copper at pH 5 and with copper and zinc at pH 9. An interference study for both determinations was carried out. The developed work was also applied to natural waters and three certified reference water samples. Subsequently, a multi-pumping flow system (MPFS) coupled with a LWCC was developed for the determination of titanium. This determination was based on the colorimetric reaction of titanium with chromotropic acid and the absorbance measurements were carried out at 425 nm. An interference study was performed in order to evaluate possible interferences. The developed procedure was applied to natural waters as well as to sunscreen formulations (the results were compared with the reference procedure). The accuracy was assessed with one certified lake sediment. The development of a spectrophotmetric method for bromate determination in waters at trace levels was the last work of this thesis. With this objective, a LWCC was coupled to a MPFS. The proposed methodology was based on a colorimetric reaction and two different colour reagents were tested, chlorpromazine and trifluoperazine. The lack of repeatability detected in this approach led to the development of a FIA approach in order to find out the reasons of this occurrence.
Language: English
Field: Chemistry
Open Access status: green
OpenAlex ID: W6981704807
Cites: 266
Cited by:
Related to: 10