Monte Carlo modellering voor patiëntendosimetrie van dentale en maxillofaciale Cone Beam Computed Tomography beeldvorming bij kinderen.
Year: 2018
Type: dissertation
Abstract: The aim of this project is to perform patient-specific dosimetry by accurately calculating organ and effective radiation doses in dental Cone Beam Computed Tomography (CBCT) and to estimate the radiation induced cancer risk. An existing Monte Carlo framework will be customized towards patient specific dosimetry. The customization involves the registration of the CBCT dataset with a database of full head voxel models based on anthropomorphic phantoms and real-life patients with full head scans. The voxel models will be used to simulate the patient specific exposure factors extracted from the DICOM header of the CBCT dataset and will also extrapolate the limited FOV of the actual scan, which may not coverthe full head and can be as small as 4cm in diameter and 3 cm in height, to represent a complete head. An algorithm will detect the best fitting voxel model for each individual. The absorbed radiation dose will thenbe calculated at selected positions in the voxel phantom or in semi-automatically segmented radiosensitive organs. The MC framework will be validated against experimental data in two stages. Anthropomorphic phantoms will be used to measure organ doses using thermoluminence dosimetry (TLD) for a range of CBCT units and clinical protocols. The Anthropomorphic phantoms will then be voxelised and organ doses will be calculated using MC simulation. In a second stage, eye and skin TLD dosimetry will be performed to real patients. The CBCT images of these patients will be used to generate voxel models and to estimate organ and skin doses via MC calculation. The calculated and measured organ doses will be compared and possible improvements to the MC framework will be investigated. Taking into account a large series of patient data, paediatric agecategories will be determined and the average-standard patient of each category will be specified based on the distribution of the size, shape,mass and volume of the skull and other radiosensitive organs. The resulting set of average patients will be compared with anatomical reference values for paediatric patients (ICRP 2003) and standard voxel phantoms for each category will be created. Using patient data and validated voxelphantoms, the framework can be expanded towards other/new system parameters such as other filters, beam geometries, scatter reduction techniques or mono-energetic imaging and recommendations on protocol optimizationfor different clinical applications will be proposed. Using the effective dose estimation for each patient along and taking into accountthe gender and the age at exposure, the Lifetime Attributable Risk (LAR) for cancer induction or mortality will be estimated. In addition, organ specific cancer risk models will be applied to the estimated organ dose as there is a considerable variability in the age-risk relation for different organs. From the uncertainty on the estimated risks, the approximations associated with the MC framework and the difference between organ doses using patient specific versus standard phantoms, the feasibilityof using this project as a first step of setting up a long term epidemiological study of cancer risk in dental radiology will be investigated.
Source: Lirias
Author: Stratis, A.
Institution: KU Leuven
Language: English
Subfield: Oral Surgery
Field: Dentistry
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W6983547668
