Muscle’s Force Profile-Based Stimulation for Motorized FES-Cycling
Year: 2024
Type: conference-paper
Abstract: Introduction: Early onset of muscle fatigue and low power output, attributed to non-physiological recruitment of motor units, represent major impediments to the efficacy of functional electrical stimulation (FES) for individuals with motor neurological disorders. This work presents a preliminary case study aimed at comparing fatigue and power during motorassisted FES-cycling using muscle’s force profile-based stimulation against conventional constant intensity stimulation. Methods: Two large surface electrodes measuring 5x18 cm² were placed over the quadriceps femoris (QF) muscle group of both legs of an individual with spinal cord injury (C7-C8, AIS: B). The subject was seated in a modified recumbent tricycle with the legs secured to the custom-built cycling ergometer equipped with force-torque measuring pedals synchronized with the MotiMove stimulator. The minimum intensity that produced visible muscle contraction was designated as the motor threshold (25 mA). Then, the cycling cadence was set to 35 rpm, using a customized LabVIEW interface, and maintained by the motor throughout all tests. Following a 3-minute passive cycling warm-up, an intensity of 70 mA was applied to both QFs over three complete motor-assisted cycles (0 to 360°). The force recorded during the passive phase was subtracted from that during the stimulation phase to establish the muscle’s force profile (MFP) for each leg, corresponding to the crank angle [1]. The MFP for each leg was normalized and interpolated using a 4th-order Fourier series in MATLAB as a function of crank angle. The normalized signal was then scaled up by a factor of 110 (the maximum intensity in mA). Any negative values were removed to prevent counterproductive muscle stimulation. A 110-degree window within which the rectified interpolated signal had the maximum integral was identified to determine the start and stop angles. The shape of the stimulation then followed this rectified interpolated signal (MFP-based stimulation). To ensure an equivalent amount of charge during constant stimulation, the average intensity of the MFP-based stimulation was calculated and used as the constant intensity. To account for muscle response delay, constant stimulation was applied at 35 rpm, and the lag between the start of stimulation and force generation was recorded and calculated. A preliminary stimulation at the motor threshold intensity, covering the muscle delay period, was applied before both MFP-based and constant stimulations to prime the muscles for contraction within the desired range (Figure 1). Participants underwent four trials, two MFP-based and two constant intensities, separated by a 10-minute rest period. Each trial consisted of a 1.5-minute passive cycling (warm-up) phase followed by a 1.5-minute stimulation phase. The order of trials was Constant-MFP-MFP-Constant. The fatigue index (FI) was calculated for each trial as the ratio of the decline in generated power from the first (PF) to the last (PL) 30 seconds, normalized to PF. Additionally, the average power output during each trial (Pm) was measured for both stimulation types. Results: The average Pm for MFP-based intensity was 13.06 W, representing a 17.52% increase compared to the constant intensity (11.11 W). The average FI (%) for MFPbased intensity and constant intensity were 37.06% and 45.24%, respectively. Discussion and conclusion: These findings suggest that stimulating muscles with the intensity proportional to the muscle’s force profile not only leads to augmented power output but also to slightly reduced fatigue, even though the input charge remained consistent across methods. Future research will extend these findings to larger cohorts.
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W6983604970