Year: 2023
Type: dissertation
Abstract: Hypersonic propulsion is a topic of growing interest with current and potential applications in defense, atmospheric travel, and planetary exploration. However, hypersonic vehicles undergo extreme flow conditions that are both hard to model and measure. Absorption spectroscopy is a diagnostic method with the ability to measure within the harsh conditions of hypersonic propulsion systems. It is an optical technique that provides non-intrusive, in-situ measurements with relatively simple optical access. Absorption spectroscopy utilizes the absorption of light at optical frequencies that are resonant with molecular quantum energy level transitions. The absorption at these frequencies produce features that can change shape, size, and position depending on the velocity, temperature, pressure, and species’ mole fraction of the sample. This allows absorption spectroscopy to provide a comprehensive picture of a flow from a single sensor. Dual frequency comb spectroscopy (DCS) is an emerging form of absorption spectroscopy that can provide particularly low uncertainties across these flow parameter measurements. DCS utilizes frequency comb lasers that provide broadband light and an extremely accurate, tightly spaced, stable frequency axis that work together to lower uncertainty by capturing a multitude of absorption features with an unprecedented combination of accuracy and resolution. The low uncertainties across all four flow parameters mentioned above can be leveraged to calculate air mass flux which is of particular importance for air-breathing hypersonic engines i.e. scramjets or ramjets. Additionally, DCS measurements can provide spatial resolution corresponding to the line-of-sight of the measurement which is important for capturing hypersonic flow phenonema with spatial gradients. In the first half of this thesis, I use a DCS instrument which measures near-IR H2O absorption features in a direct-connect, grounded test ramjet. In Ch. 2, we demonstrate DCS measurements of velocity, temperature, pressure, H2O species’ mole fraction, and ultimately air mass flux of a simple flow condition in the isolator of the test ramjet. The simple flow conditions, which consists of a large flat core region and small boundary layers, allow for comparison with upstream facility air mass flux measurements which DCS measurements show strong agreement with. We also do a vertical scan of the boundary layer to demonstrate the spatial capabilities of the DCS technique. These measurements represent the first DCS measurements in a ramjet engine and the first DCS measurements of pressure and air mass flux. In Ch. 3, we place a distortion generator before the isolator to create a shock train which creates harsh gradients in many of the flow parameters. We measure a 2D spatial profile of one of the oblique shocks and demonstrate that DCS matches expected trends across all parameters. We also measure a 2D velocity spatial profile in the combustor of the ramjet engine, where higher noise and temperatures increase the difficulty of the measurement. Again, DCS matches expected trends. In Ch. 4, we utilize a new near-IR H2O absorption database to enable measurements of other flow parameters in the combustor including temperature, pressure, and H2O mole fraction. We demonstrate that this new database provides better fits to high temperature data than other databases. In these chapters, we also perform a thorough uncertainty analysis of these measurements and also provide comparisons against CFD. This work demonstrates the potential of DCS to verify models in test environments and eventually possibly act as in-flight sensors. In the second half of the thesis, I detail experiments that build upon the work of the first half of my thesis and push the boundaries of DCS spectroscopy in hypersonics towards in-flight sensing. In Ch. 5, I construct and deploy a near-visible wavelength DCS system that measures O2 absorption features. Measuring O2 is a step towards future in-flight ramjet DCS sensors as ramjets fly in the stratosphere where H2O is not available. Here, we demonstrate that despite the low absorbance of O2 we can take advantage of DCS characteristics to produce low enough uncertainty to validate measurements with facility predictions. In Ch. 6, I discuss the first single-beam laser absorption velocimetry. Prior absorption spectroscopy velocity measurements rely on a crossed two-beam or retroreflector setup to lower velocity uncertainty due to instrument and spectroscopic error. Here, we improve accuracy of the DCS mobile system frequency axis and utilize the new DCS-based improved spectroscopic model discussed in Ch. 4 to demonstrate one-beam measurements which can lower hardware requirements (which is important for an in-flight sensor) and improve spatial resolution of DCS sensing in hypersonics.
Author: Yun, David
Language: English
Subfield: Spectroscopy
Field: Chemistry
Domain: Physical Sciences
Open Access status: green
Awards: G2836377447, G8289759875
OpenAlex ID: W6989393052
