Mikroskopisches Korrosionsmodell für Magnesiumlegierungen und Grenzen der elektrochemischen Rauschanalyse
Year: 2012
Type: dissertation
Abstract: Due to outstanding mechanical properties and biocompatibility, magnesium alloys are very promising candidates for medical implant materials.One major challenge is to properly adapt the corrosion rate to the clinical requirements.Therefore, it is essential to dispose of a comprehensive understanding of degradation processes in physiologic environments, which is the target of this work.For the purpose of simulating in vivo conditions, simulated body uids were used as electrolytes.Besides electrochemical methods and ion chromatography, optical and scanning electron microscopy as well as energy dispersive X-Ray analysis were used as analytical tools.On this basis, a comprehensive, microscopic model of the corrosion of magnesium alloys in simulated body uids was formulated.The model describes cathodic centers, which cause the precipitation of volcanoshaped structures and inuence the build-up of a corrosion layer.Zr-rich phases (containing parts of Fe and Ni) in case of alloy WE43 and Fe-rich phases in case of pure magnesium act as micro-cathodes.Localized corrosion with vigorous hydrogen evolution and protected areas in the immediate surrounding of cathodic centers were observed by means of a combination of cross-sections and surface analysis.In between, degradation of bulk material takes place.In agreement with in vivo results for stents, a corrosion double-layer builds up, which mainly comprises Mg(OH)2, Mg3(PO4)2 und Ca3(PO4)2.The microscopic model is guilty for all rare-earth magnesium alloys and allows to predict the corrosion behavior of magnesium alloys on the basis of initial corrosion processes.Many cathodic centers in homogeneous distribution and with enhanced protected areas in their surrounding increase the corrosion resistance of magnesium alloys with a high fraction of rare earths.Alloying of rare earths inuences the distribution of intermetallic precipitations and the constitution of the matrix towards more stable oxide layers and smaller galvanic coupling between particles and matrix.Experiments under ow underline the sensitivity of magnesium corrosion to the local pH value and clarify the inuence of dynamic exposure conditions.For localized corrosion phenomena of Mg alloys, the test method of electrochemical noise can be considered.Magnesium corrosion in aqueous electrolytes is characterized by vigorous hydrogen gas evolution.Noise signals are dominated by hydrogen bubble attachment, growth and detachment.The signal contribution of charge transfer events is inferior.Gas bubble evolution, however, depends on multiple factors.Besides the corrosion rate, surface porosity, surface tension and electrolyte viscosity inuence gas evolution behavior.The informative value of noise analyis for magnesium alloy corrosion in SBF is limited.A reliable interpretation requires a second, independant in situ method.Inhaltsverzeichnis Einleitung I. Korrosion von Magnesiumlegierungen in körperähnlichen Elektrolyten 1. Hinführung1.1.Eigenschaften und Einsatz von Magnesiumlegierungen 1.2.Anwendung als medizinische Implantatmaterialien . . 2. Grundlagen 2.1.Korrosionsreaktionen in wässrigen Elektrolyten . . . .2.2.Einussfaktoren auf die Korrosionsrate . . . . . . . . .3. Material und Methoden 3.1.Werkstopräparation . . . .
Author: Hermann Kalb
Institution: Friedrich-Alexander-Universität Erlangen-Nürnberg
Language: German
Subfield: Biomaterials
Field: Materials Science
Domain: Physical Sciences
Keywords: magnesium alloys, corrosion, simulated body fluid, rare earth magnesium alloys, WE43 magnesium alloy, localized corrosion, intermetallic precipitates, hydrogen evolution reaction, electrochemical noise, corrosion rate, biomedical implants, stents, pH dependence, galvanic coupling, in situ monitoring, ion chromatography, scanning electron microscopy
Open Access status: green
OpenAlex ID: W6992780890