Work

Utilisation des jauges de déformation et des centrales inertielles pour améliorer l'identification des intentions de mouvement

Year: 2021
Type: dissertation
Abstract: Recent studies have shown that signals obtained from electromyography sensors can be used to identify human movement intentions. These sensors are often paired with other types of sensors to increase the dimensionality of the data. The combination of surface electromyography sensors and inertial units is the most commonly used multimodal sensor technique. Nowadays, this combination is used to identify the intention of movement in humans, e.g. to control their prosthesis or exoskeleton. However, electromyography sensors have various drawbacks. These sensors generally require two electrodes placed at two sites on the skin, which makes them bulky. Additionally, the frequency of acquisition of electromyography signals is generally about 1000Hz which reduces the number of sensors that can be used simultaneously. Indeed, on-board devices generally use 2 or 3 of these sensors because of the high memory and computing power required to process the information. These sensors are also very sensitive to noise. The variable nature of electromyography signals has motivated the search for alternatives that can utilize multiple sensors operating at lower frequencies for everyday applications. The objective of this study is to develop a newly portable system to identify movement intentions by combining strain gauges and inertial units. The system is composed of 1. two bracelets each using six strain gauges, connected to a flexible PCB and 2. two inertial units. Physiologically, strain gauges measure the deformation of the skin due to muscle contractions while inertial units provide additional data on the kinematics of movement. Data was collected from seven healthy subjects. A classification algorithm based on a combination of a recurrent neural network and a convolutional neural network has identified nine upper limb movements as well as one rest movement. The classification algorithm achieved a classification accuracy of 89.31% using only the signals from the strain gauges. By adding the kinematic information yielded an increase in classification accuracy of 5.74% to obtain a final accuracy of 95.05%. These results show the great potential of using such a system to accurately identify movement intentions.
Language: French
Open Access status: green
OpenAlex ID: W6997155893
Cites: 71
Cited by:
Related to: 9