Training thresholds in runners
Year: 1992
Type: dissertation
Abstract: respiratory quotient SD standard deviation sec second ST slow twitch TV treadmill velocity VC02 volume of carbon dioxide VE volume of expired air VE/VC02 ventilatory equivalent for carbon dioxide VE/V02 ventilatory equivalent for oxygen VI volume of inspired air VF ventilatory frequency VO2 oxygen uptake V02max maximal oxygen uptake Vd heart rate deflection point VT ventilatory threshold %C02 percent of carbon dioxide %02 percent of oxygen IV ABSTRACT Ventilatory threshold (VT) and heart rate deflection point (Vd) have recently been used interchangeably as a means to regulate continuous running training intensities.There is also evidence to suggest that these variables may occur at different exercise intensities suggesting that the physiological strain imposed by these exercise intensities may not be the same.Therefore, the purpose of this study was to compare: 1) the oxygen uptake (V02), %V02max, heart rate (HR), %HRmax, and treadmill velocity (TV) at which VT and Vd occur, 2) the validity and reliability of VT and Vd, by test-retest comparison, and 3) the lactate, HR, and gas exchange responses to constant work load exercise (CWL) at a speed which corresponds either with the VT (CWLVT) or Vd (CWLVd).Twenty male well trained runners were tested on four different occasions: a) an incremental treadmill test to exhaustion was carried out to determine VT, Vd, and peak V02, b) 48 hours following the peak V02 test VT and Vd reproducibility was tested by employing a submaximal test (i.e.95%V02max), c) constant work load measures were performed on two consecutive days, in a random order, immediately after the submaximal test.The VT was determined as the work load before systematic increase in FE02 (fractional expired oxygen) without a concomitant increase in FEC02 (fractional expired carbon dioxide).The work load at which HR departed from linearity was considered as Vd.A paired t test showed that VT was significantly lower than Vd when expressed as V02, HR, and TV (p<0.05).Direct correlations yielded significant relationships (p<0.05) between VT and Vd for all measures apart from %HRmax and %V02max.The highest correlation was found for TV (r=0.87).The treadmill velocity also provided the highest test-retest correlation for expressing VT (r=0.95) followed by HR (r=0.94),V02 and %HRmax V (r=0.86), and %V02max (r=0.75).Vd variables were not equally reproducible being HR (r=0.75),TV (r=0.69),V02 (r=0.52),%HRmax (r=0.29) and %V02max (r=0.07).VT was noted in all tests, three subjects failed to demonstrate Vd in at least one of the evaluations while one subject did not present Vd in both tests.Blood lactate concentration during CWL trials after initial increase stabilised at different levels without any substantial trend in the individual lactate curves, except for the CWLVd where lactate values at thelOh minute of exercise were all greater than the resting value.Analysis of variance showed that the lactate values at CWLVT were significantly lower for all data points, except the resting value, compared with the corresponding CWLVd values.Volume of expired air (VE), ventilatory frequency (VF), respiratory exchange ratio (R), V02, ventilatory equivalent for oxygen (VE/V02) and ventilatory equivalent for carbon dioxide (VE/VC02) values were significantly higher at CWLVd compared with the respective CWLVT values at all measured data points.It is concluded that in well trained runners: I) deflection in heart rate does not always occur and when it does it correlates with ventilatory threshold but does not coincide.II) athletes can maintain a running speed equivalent to CWLVd for extended periods of time.This results in greater physiological strain than the corresponding exercise at VT. VI
Author: Zacharogiannis, Elias
Institution: University of St Andrews
Language: English
Subfield: Physiology (medical)
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7006401600
