Development of an Attenuated Total Reflection Infrared Sensor for the Measurement of Neutral Lipids in Microalgae

Year: 2015
Type: dissertation
Abstract: Algal lipids can be used to produce biofuels and are considered a potential source of energy that could supplant some fossil fuel. Algae can be produced in large ponds, and their nutrient supply can be controlled so as to maximize lipid content. An automated, real-time, lipid-content measuring technique, as opposed to the current time-consuming and labor-intensive laboratory methods, is needed to efficiently control nutrient addition to ponds. Spectroscopy was used in this research to establish that optoelectronic methods could be used for real-time sensing of neutral-lipid content in microalgae. A Fourier-Transform Infrared (FTIR) spectrometer was used with an attenuated-total-reflection (ATR) attachment to acquire spectra from samples of varying lipid contents in two algae species, Nannochloris oculata and Desmid. Measurements at three absorbance bands (2920 cm^-1, 2855 cm^-1, and 1742 cm^-1) were correlated to lipid content, as measured with gas chromatography (GC). Several estimation models including various groupings of the three bands were found to provide reasonably good estimations of lipid content, suggesting that a sensor using this technique could be used for real-time measurements. Ultimately a simple, fast, low-cost, infrared (IR) sensor was developed. The sensor uses an integrated convective heater to dry algae-mixture droplets onto an internal-reflection element (IRE). The main components of the sensor are an infrared light-emitting diode (LED) that emits energy at 2940 cm^-1, a right-angle zinc-selenide IRE, and a photodiode to measure energy reflected through the IRE. Sensor measurements were analyzed with simple linear regression (SLR) to determine their relationship with lipid content. These analyses, like those with spectroscopic data, revealed moderate estimation performance for Nannochloris oculata, (R2 = 0.50; RMSE = 37.7 mg/g), but better performance for Desmid (R2 = 0.73; RMSE = 42.4 mg/g). A generalized model of sensor measurements on both species had poorer performance (R2 = 0.29; RMSE = 59.12 mg/g), but it showed a promising linear trend between sensor measurements and lipid content across multiple species. The time required for the sensor to take a measurement of one microalgae sample was 120 minutes, far less than that required with conventional laboratory methods. The sensor performance was evaluated against lipid content in samples of two microalgae species (Nannochloris oculata and Desmid) of various lipid contents, which were measured with gas chromatography (GC). Simple linear regression (SLR) analyses were used to determine the relationship between sensor measurements and lipid content. The regression analyses revealed moderate prediction performance for Nannochloris oculata, with an R2 value of 0.50 and RMSE value of 37.72 mg/g for that species. There was relatively better prediction performance for Desmid, with an R2 value of 0.73 and RMSE value 42.36 mg/g. A generalized model was constructed to relate the sensor measurements of both algae species to lipid content using the simple linear regression analyses. The model showed relatively lower prediction performance, with an R2 value of 0.29 and RMSE value of 59.12 mg/g. Despite the inclusion of two different microalgae species in the generalized model, the model was able to show a promising linear correlation trend between sensor measurements and lipid content across the two algae species. Similarly, a Nicolet FTIR 6700 spectrometer was used to acquire ATR-FTIR spectra for Nannochloris oculata and Desmid algae samples of various lipid contents. The absorbances at three absorbance bands (2920 cm-1, 2855 cm-1, and 1742 cm-1) were correlated to lipid content verified using a best subset multiple regression analysis. In general, the results indicated that the two-variable models outperformed single and three-variable models in prediction performance. The best prediction model for Nannochloris oculata was the two-variable model containing the 2885 cm-1 and 1742 cm-1 absorbance bands, with R2 value of 0.49 and RMSE value of 39.51 mg/g. The best prediction model for Desmid was the two-variable model containing the 2920 cm-1 and 2855 cm-1absorbance bands, with an R2 value of 0.62 and RMSE value of 52.37 mg/g. The best prediction model for the generalized model of both algae species Nannochloris and Desmid was the two-variable model containing the 2920cm-1 and 1742 cm-1 absorbance bands, with R2 value of 0.27 and RMSE value of 61.28 mg/g. Overall, the results showed that the sensor demonstrated reasonably good prediction performance compared to the Nicolet ATR-FTIR spectrometer. In addition, the total time required for the sensor to take a measurement of one microalgae sample was 120 minutes, which is by far less than the time required by conventional laboratory methods. The reduction in measurement time was partially due to the use of the convection heat drying system integrated in the ATR-IR sensor. In order to enhance the performance of the developed ATR-IR sensor, a number of recommendations were proposed for any future development to the sensor. Those were the inclusion of one more diagnostic absorbance band (1742 cm-1) and the use of a multiple internal reflection element, which would increase the sensor’s sensitivity, increase signal to noise ratio, and raise the sensor capabilities for measuring lipid content of algae samples of low biomass concentrations.
Language: English
Field: Chemistry
Open Access status: green
OpenAlex ID: W7009087136
Cites: 36
Cited by:
Related to: 10