Determination of crystalline structure of calcium carbonate obtained from drinking water
Year: 2008
Type: article
Abstract: Sample of scale which taken from house boiler is examined. This scale is made by warming drinking water from water-supply system of the -city of Belgrade - New Belgrade. Examinations on atomic absorption spectrophotometer (AAS) showed that there was mostly calcium, like CaO, for 48.90 % of mass which means calculated on contents CaCO3 takes 87.32 % of mass. Research on diffraction meter showed that scale is composed of CaCO3 (in % of mass) (85.25%), MgCO3 (11.05%), FeCO3 (1.90%) and MnCO3 (1.80%). It was also proved that scale is mixture of 66.92 % Mg calcite and 33.07 % aragonite. This structure is result of fact that Mg calcite and aragonite are become in quiet conditions of sedimentation of half shut skin-deep water surrounding on temperature between 60 and 100°C (nearest about 80°C) and low pressure.
Authors: Rajković, Miloš, Lačnjevac, Uroš Č., Baščarević, Zvezdana, Rajković, Teodora M., Tošković, Dragan V., Stanojević, Dušan D.
Language: English
Subfield: Biomaterials
Field: Materials Science
Domain: Physical Sciences
Open Access status: green