Abstract: Around 1.4 to 32% of adults over the age of 60 will experience a spine deformity, which is represented by an abnormal curvature in one or more sections of the vertebral column. When treating this issue, instrumentation with pedicle screws and rods are used to realign and stabilize the spine, in order to lead to fusion. However, between 0.8 to 27% of the cases of pedicle screw fixation fail and are mainly associated with the screw trajectory and vertebra deformity, the forces involved and the mechanical properties of the bone tissue. To evaluate the fixation of pedicle screws, standard pullout testing is used in experimental testing with cadaveric or synthetic samples. This, however, limits the representation of in vivo human vertebral characteristics. Finite element modeling offers an alternative solution that provides detailed biomechanical analysis of the spine and can numerically simulate pullout tests to evaluate pedicle screw fixation. Several studies have developed single vertebra or full spine finite element models (FEMs) to evaluate vertebral strength, predict vertebral fracture and even screw failure. These models are generally designed with a generic geometry and average mechanical properties, generally acquired using medical imaging modalities such as computed tomography (CT) or quantitative computed tomography (qCT). Patient-specific properties can be obtained via these modalities but impose a high risk of ionizing radiation exposure to the patient, limiting their use. A great variability of bone density has been observed in the trabecular vertebral bone. Bone mineral density seems to be higher in the peripheral regions, whereas the central regions present lower values. Because bone quality greatly varies between the vertebral region and between individuals, the concept of patient-specific modeling of bone properties has grown interest in finite element modeling. A new low-dose imaging system is presented in this project and has the capacity of providing dual-energy (DE) bi-planar (lateral and frontal) radiographs, which are acquired simultaneously on a standing patient. A dual-energy modality allows the analysis of bone density of the vertebrae as it calibrates the radiographs accordingly with the density of hydroxyapatite (HA). Thus, the objective of this research project is to develop and validate the feasibility of integrating patient-specific mechanical properties of the bone tissue using dual-energy radiography in a 3D vertebral FEM to improve pedicle screw fixation. An image simulator provided by the company of the imaging system was used to generate bi-planar radiographs, in order to work in a controlled environment. Using a test case of a patient CT scan from an open access database, the image simulator generated bi-planar polymethyl-methacrylate (PMMA)- and aluminum-calibrated radiographs to simulate soft and bone tissue, respectively, as well as HA-calibrated radiographs to simulate bone mineral density. Therefore, pixels values from the images were calibrated in g/cm². Four isotropic FEMs of the 3rd lumbar (L3) vertebra were created with two different trabecular bone distributions derived from the DE radiographs or from published trabecular bone mineral densities: 1) averaged (homogeneous) and 2) averaged over small regions of interest (heterogenous). The latter allows an individual visualization of the different subregions of the vertebral body and the posterior elements, as well as of the pedicle regions. Geometrical measurements allowed the estimation of volumetric bone mineral density (vBMD) for each region of the vertebra. After evaluating several mathematical relationships that relate the Young's modulus and the vBMD, the power-law equation of Keller et al., (1994) was selected. Other mechanical properties such as the yield stress or Poisson's ratio were obtained from previous studies on experimental tests. Pedicle screw pullout simulation was performed on the four models in which the screw was placed in right pedicle. The internal maximum stress distribution, the bone-screw interface initial stiffness and the peak pullout force were calculated and compared between the models. Results showed that models with properties derived from DE radiographs, when compared to the reference models, respectively increase the bone-screw interface stiffness on the homogeneous (5262 vs. 2232 N/mm) and the heterogeneous (4830 vs. 2314 N/mm) models. The peak pullout force also increases for the homogeneous (418 vs. 298 N) and heterogeneous (511 vs. 371 N) models. Additionally, a higher stress distribution was observed around the screw threads on the models with properties derived from DE radiographs. The posterior elements, the pedicles and the posterior regions of the vertebral body, reported higher stiffness and peak pullout force on the heterogeneous models compared to the heterogeneous models. These results are attributed to the posterior subregions of the vertebral body which provide better resistance at the first quarter of the pedicle screw length during simulated pullout. This can be confirmed as well with the lower stress values found around the screw threads on the heterogeneous model with properties derived from DE radiographs. All results were within acceptable range when compared to experimental and numerical studies. Integrating patient-specific mechanical properties in a vertebral FEM with a heterogeneous distribution allows a realistic perspective for orthopedical surgical planning to otherwise underestimated results in a homogeneous distribution. The novel low-dose imaging system has the advantage of providing HA density-calibrated radiographs allowing detailed quantification of the mechanical properties of the vertebral bone. Further research should concentrate on evaluating the imaging system's feasibility on other regions of the body such as the pelvis or limbs. Automatic algorithms that allow fast and accurate calculation of the bone mineral density from patient-specific radiographs would provide better results to integrate into numerical models.
Author: Solorzano Barrera, Carolina
Institution: Polytechnique Montréal
Language: French
Subfield: Surgery
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7015716093