Work

Beeinflussung der Titankarbid-Schichtdicke bei der HFCVD-Diamantbeschichtung von Titan durch Oberflächenvorbehandlungen und Variation der Beschichtungsparameter

Year: 2013
Type: dissertation
Abstract: In recent years the application of boron-doped diamond electrodes in drinking water purification has gained great interest. However, the high costs associated with the conventionally used niobium substrate have prevented a widespread commercial use. Although titanium has been suggested as a cheaper viable alternative to niobium it has been found to reduce the lifetime of the diamond electrodes. This lifetime reduction is the result of the electrochemical dissolution of the titanium carbide interlayer, which is formed in situ during the chemical vapor deposition (CVD) diamond coating process on the titanium substrate, leading to the delamination of the diamond layer. In order to improve the lifetime of titanium-based diamond electrodes a reduction of the titanium carbide thickness is required. The research within this thesis examines the formation of the TiC interlayer during the diamond coating process after a surface oxidation pretreatment of the titanium substrate and accordingly by varying the coating parameters. During the oxidation pretreatment the oxygen reacts with the titanium substrate forming an oxidic surface layer and an oxygen diffusion zone. The subsequent diamond coating is carried out either directly on the oxide layer or after etching the oxide of the titanium substrate. The methane flow in the first hour of the diamond coating was varied to determine the influence of carbon on the formation of the TiC interlayer. The investigations cover the phase analysis and thickness of the surface layers just as microstructure, microhardness and oxygen content of the substrate material. The respective results are incorporated into a model for the formation and growth process of titanium carbide during the diamond coating taking into account the free reaction enthalpies. Finally, simple electrochemical tests of the diamond electrodes were undertaken to test the suitability of the modified pretreatment and coating processes for use in drinking water purification. The reduction of the TiC interlayer thickness could be achieved in all cases regardless of the utilized mechanism. It was found that an oxide layer on the substrate surface converts during the diamond coating into titanium carbide through the formation of lower titanium oxides similar to a carbothermal reduction. The oxygen in the oxide gradually dissolves in the titanium substrate and forms an α case. Due to the conversion of the surface layer the TiC thickness equalize approximately the thickness of the oxide. In this case a decrease of the TiC thickness is achieved particularly at high substrate temperatures compared to samples without oxide. Unfortunately the pore structure of the oxide is transferred to the titanium carbide, which reduces the adhesion to the substrate and thus the lifetime of the electrodes. In a second pretreatment the oxide layer is etched off the substrate surface, so that only the oxygen diffusion zone is present in the titanium substrate. In this oxygen-enriched zone, called α case, the titanium substrate does not convert into the β phase during the diamond coating process, although due to hydrogen uptake the β transus-temperature is exceeded in the middle of the sample. As the formation of the titanium carbide on α-titanium is thermodynamically less favorable than on β titanium this results in a reduction of the TiC interlayer thickness. Furthermore, as long as the size of the oxygen-diffusion zone is greater than the typically obtained TiC thickness in the diamond coating the oxidation temperature for the production of the oxygen diffusion zone is irrelevant. A stabilization of the α-phase can also be achieved by an incorporation of carbon in the titanium substrate. Therefore the methane flow in the first hour of the CVD process is increased. A Higher methane content during diamond coating prevents the etching of diamond nuclei and reduces the substrate temperature. As a result the diamond layer, which is formed concurrently with the titanium carbide, is completed earlier so that the titanium carbide growth is impeded due to the low diffusion of carbon in diamond. Hence, this samples show a reduced titanium carbide thickness and an extended electrode lifetime in the electrochemical test. Overall, this work demonstrates that the titanium carbide thickness can be influenced by an additional pretreatment before the diamond coating and by the choice of the coating parameter. However, for a widespread use of titanium-based diamond electrodes in water purification not only the TiC thickness but also factors as the thermal stress and the connection of the surface layers, the electrolyte and several other factors have to be taken into account.
Author: Neuerer, Katharina
Language: German
Open Access status: green
OpenAlex ID: W7017766416
Cites: 170
Cited by: 1
Related to: 10