Work

Modellierung und Regelung selbstgeführter, höherstufiger Multiterminal-HGÜ-Systeme mit Gleichspannungszwischenkreis

Year: 2018
Type: dissertation
Abstract: This thesis provides a comprehensive approach for modelling and control design of self-commutated multilevel VSC multiterminal HVDC systems. The mathematical models of the systems are developed in the Laplace Domain as it offers appropriate opportunities regarding implementation in dynamic system analysis tools and the subsequent control design process. Based on fundamental assumptions, such as the advantage of the application of controlled voltage sources rather than a series connection of several hundred submodules, models for the AC and DC side of the MMC as well as for the DC network are determined. Since the dq-transformation of AC signals provides zero-frequency quantities under steady state conditions, AC side models are obtained in the dq-frame. The DC network model is based on the concatenation of Pi- or T-sections respectively and is therefore easily extendable to parallel connected and meshed multiterminal systems. Regarding the connection of the AC and DC side models, two options are investigated. Firstly, the approach of the instantaneous active power equilibrium of the MMC is considered. Secondly, the model for the energy storage of the submodules in the converter arms of the MMC is introduced. From this, two different models can be derived. The first is a more simplified model consisting of the AC side model of the MMC, the model of the DC network and their connection via the instantaneous active power equilibrium. The second is a detailed model which takes into account the AC and DC side equivalent circuit of the MMC, the DC network dynamics and applies a connection via the energy storage of the submodules within the converter arms. The second part of this thesis discusses the control design of self-commutated multilevel VSC multiterminal HVDC systems. System controllers are determined according to sophisticated control design approaches such as the symmetrical optimum or amplitude optimum, respectively. Active power, converter energy and DC voltage can be controlled via a number of subordinated current controllers. Out of four investigated scenarios, two scenarios produced favorable results. The so-called scenario 2 controls active power via the subordinated AC grid controller in the dq-frame and the converter energy via the differential current controller on the DC side. This set-up delivers the best support to an AC grid according to its reaction to AC faults. Scenario 4 controls the converter energy via the AC grid controller and the active power via the differential current controller. This produces the best support to the DC grid since its reaction to DC faults is much faster than in scenario 2. The Voltage Margin Method and Voltage Droop Control are analyzed for multiterminal systems and an approach for the arrangement of the characteristic curves as well as for the determination of the droop constants is carried out. This approach guarantees an adapted contribution of the respective converters to the DC voltage control of the entire system according to their nominal operating point and distance to their power limits. The mathematical models developed and the appropriate control schemes are tested and a comparison with an EMT-model shows good matching results as well as the consistence of the dynamic behavior of the entire system.
Author: Christoph Hahn
Language: German
Open Access status: green
OpenAlex ID: W7020723988
Cites: 90
Cited by: 5
Related to: 10