Year: 2013
Type: dissertation
Abstract: In neuroscience, microinfusions of drugs directly into the central nervous system of awake animals are often used to unravel brain functions related to behavior. In this respect, implantable multifunctional microprobes enabling drug delivery alongside electrophysiological recording of neural activity are desirable. However, whereas small, skull-mounted transmitters (headstages) for wireless electrophysiological recordings are already commercially available, drug delivery relies still mostly on tethered liquid infusion systems with a stationary syringe pump, possibly interfering with behavior. Ideally, one headstage can be used for both electrophysiology as well as control of drug delivery. To address the aspect of drug delivery, this thesis presents the NeuroMedicator, a micropump system with an application-specific, comb-like silicon microprobe. With outer dimensions of 20 × 17.5 × 5 µm³, the device is small and lightweight enough to be placed directly on the skull of a rat. The operational concept of the NeuroMedicator is based on 2 × 8 discrete liquid reservoirs interconnected in a pearl-chain-like manner whose contents can be infused on demand. Thereby, the drug liquid is loaded to the reservoirs prior to implantation. After implantation and electrical connection, individual 0.25 µL infusions can be sequentially released through the two shafts of the silicon microprobe. Delivery of the reservoir contents is realized by thermally expandable Expancel® microspheres embedded into an elastic polydimethylsiloxane (PDMS) matrix. By applying short heating pulses to the composite underneath a reservoir, the resulting irreversible expansion displaces the liquid and releases it through the microprobe directly to the neural tissue. To enable localized energy-efficient heating, two different microheater array designs are fabricated by thin-film processing on multilayer printed circuit boards (PCBs) and subsequently evaluated. Additionally, in order to get a better understanding for the different expansion phases of the microspheres, the associated idealized thermodynamic processes are described. Microprobe designs featuring different microfluidic channel layouts and electrodes to be used with the NeuroMedicator as well as other assemblies are implemented. The microprobe comb used with the NeuroMedicator features two 8-mm-long shafts each having a cross-sectional area of 250 × 250 µm² and an integrated drug delivery channel of 50 × 50 µm² with an outlet of 25 µm in diameter. The microprobes are fabricated in a two-wafer silicon direct bonding process by applying deep reactive ion etching (DRIE), wafer grinding, and thin film processing. Following fabrication, in particular the fluidic properties of the microprobes are characterized. Furthermore, a miniaturized system assembly for the microprobes is developed which allows to demonstrate the combination of drug delivery and electrophysiological recording during in vivo functional inactivations. After implantation of the microprobe, leakage of drug by diffusion occurs due to the open outlets. In order to evaluate this, the amount of leakage as well as its effect on the NeuroMedicator is simulated for a worst case scenario. The maximum leakage within the first three days after implantation is calculated to be equivalent to less than 0.07 µL of drug solution. The development of the NeuroMedicator is implemented in two stages with two prototypes NeuroMedicator I and II which are both characterized and evaluated. The general proof-of-concept and device functionality is first demonstrated with the NeuroMedicator I being mainly based on PDMS technologies. On this basis, critical aspects such as increased storage stability of the drug liquid and practical handling issues are addressed by the NeuroMedicator II. This includes an evaluation of the barrier properties of different polymer foils. After connection to an external electronic control unit, the NeuroMedicator II provides individual metered infusions of 0.25±0.01 µL each requiring 3.375 Ws of electric energy. Finally, the NeuroMedicator II is successfully applied in the 5-choice serial reaction time task (5-CSRTT), a behavioral test of visual attention and impulsivity.
Author: Spieth, Sven
Institution: University of Freiburg
Language: English
Subfield: Cellular and Molecular Neuroscience
Field: Neuroscience
Domain: Life Sciences
Open Access status: green
OpenAlex ID: W7021214362
