Work

Safety and Efficacy of a Paclitaxel-Coated Balloon for the Treatment of Symptomatic Patients with Long Superficial Femoral Artery Disease

Year: 2025
Type: article
Abstract: Paolo Sbarzaglia,1 Mattia Galli,1,2 Elena Tenti,1 Diego Sangiorgi,1 Maria Letizia Lunetto,1 Paolo Russo,3 Armando Liso,4 Vincenzo Pernice,5 Antonio Micari,6 Fausto Castriota1 1Cardiovascular Department, Maria Cecilia Hospital, GVM Care & Research, Cotignola, Ravenna, 48033, Italy; 2Department of Medical-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Latina, 04100, Italy; 3Cardiology Unit, Maria Pia Hospital, GVM Care & Research, Torino, 10132, Italy; 4Cardiology Unit, Città di Lecce, GVM Care & Research, Lecce, 73100, Italy; 5Department of Cardiovascular Surgery, Maria Eleonora Hospital, GVM Care & Research, Palermo, 90135, Italy; 6Department of Biomedical Dental Sciences and Morphological and Functional Images, University of Messina, Messina, 98122, ItalyCorrespondence: Diego Sangiorgi, Cardiovascular Department, Maria Cecilia Hospital, GVM Care & Research, Cotignola, Ravenna, 48033, Italy, Tel +39-0545-217579, Email [email protected]: The clinical performance of drug-coated balloons (DCBs) for the treatment of femoro-popliteal lesions may depend on the specific device used. There is limited evidence on the clinical safety and efficacy of the paclitaxel-coated device Stellarex® for the treatment of long (> 180 mm) femoro-popliteal lesions.Methods: This is a single arm, prospective, open label, observational study including symptomatic patients with long femoro-popliteal lesions undergoing endovascular revascularization with Stellarex® DCB. The primary endpoints were the safety and efficacy of the DCB over time. Secondary endpoints were represented by functional outcomes.Results: Ninety-five patients (median age 72, lesion length 250 mm) were included. At 6 months after the procedure, 61% of patients were asymptomatic as defined by the Rutherford classification, decreasing over time (57% at 12 months, 56% at 24 months, 44% at 36 months). Walking Impairment Questionnaire showed a remarkable improvement at 6 months, with a decreasing trend over time. When single components were analysed, better performances were observed for distance and climbing scores throughout the study period, while speed returned to baseline levels after 24 months. EQ5D Questionnaire showed a statistically significant improvement throughout the study period (with a decreasing trend over time, as seen for Rutherford classification and Walking Impairment Questionnaire). During the 36-months follow-up, 9% of patients died, with previous limb amputation being an independent predictor of mortality (HR = 7.4, p = 0.013). One-year primary patency was 76.5%, with no significant difference compared to the reference rate of 80% (p = 0.810). Primary patency defined as PSVR ≤ 2.4 (peak systolic velocity ratio) was maintained over time (median survival time free from PSVR > 2.4 was not assessable as it exceeded the 36 months of follow-up).Conclusion: In our sample, Stellarex showed to be safe and effective and it was associated with an event rate comparable to other devices reported in literature. Keywords: superficial femoral artery disease, lower extremities artery disease, endovascular revascularization, drug-coated balloon, paclitaxel
Authors: Sbarzaglia P, Galli M, Tenti E, Sangiorgi D, Lunetto ML, Russo P, Liso A, Pernice V, Micari A, Castriota F
Language: English
Subfield: Surgery
Field: Medicine
Open Access status: green
OpenAlex ID: W7024562811
FWCI:
Cites:
Cited by:
Related to: