Work

Minute Ventilation Sensor Driven Rate Response as a Part of Cardiac Resynchronization Therapy Optimization in Older Patients

Year: 2025
Type: dissertation
Study design: Clinical Trial
Abstract: With the growing and aging of the population the prevalence of heart failure is rapidly increasing. Furthermore, a growing number of heart failure patients suffer from chronotropic incompetence (CI), defined as the inability to adequately increase heart rate to meet the demands of physical activity. An inadequate raise in heart rate is possibly one of the main limiting factors for exercise capacity in heart failure patients. Additionally, CI is shown to be an independent marker of poorer prognosis. Nevertheless, chronotropic incompetence remains often unrecognized in clinical practice. The primary mechanisms underlying CI include alterations in autonomic nervous system function and the increasing use of beta-blockers as part of optimal medical therapy for heart failure. Rate-adaptive (or rate-responsive) pacing is an established clinical treatment for patients who suffer from CI. Rate-adaptive pacemakers adjust heart rate based on physical activity, guided by one or more sensors. In this study we investigated the use of a minute ventilation (MV) sensor, to achieve as physiological heart rate response to exertion as possible. Previous studies have shown that rate adaptive pacing can improve CI. To our knowledge, no earlier studies have evaluated the use of only MV sensor in patients with cardiac resynchronization therapy (CRT-P). The main goal of this study was to evaluate whether MV sensor driven rate-responsive pacing improves exercise tolerance in elderly patients with CRT-P devices. Exercise tolerance was assessed using the 6-minute walk test (6MWT). Our secondary goal was to assess whether MV sensor driven rate-responsive pacing improves the heart rate score (HRSc), a histogram-based marker of heart rate variability. HRSc shows the proportion of time spent at the most common 10 bpm heart rate bin, with values > 70% identified as an independent predictor of worse prognosis. A total of 61 patients were included in the study, all of whom met a guideline-based indication for CRT-P. At 1-month post-implantation, patients underwent a 6MWT. A maximum heart rate < 100 bpm or < 80% of the age-predicted maximum heart rate (APMHR) was determined as chronotropic incompetence. Patients with CI were programmed to receive rate-responsive pacing (DDDR). The 6MWT was repeated at 3 months post-implantation. HRSc data was also evaluated at 1 and 3 months. CI was present in 46 out of 61 patients. In this group, MV-sensor based rate responsive pacing significantly improved 6MWT results (349 ± 132 m vs. 376 ± 128 m at 1 and 3 months, p < 0.05). Furthermore, rate-responsive pacing reduced the HRSc by 6% (p=0.02), and among patients with a baseline HRSc > 70% the reduction was 14% (p<0.001). With MV sensor-driven pacing the heart rate response to exercise in patients with CI was comparable to that of non-CI patients. Our study did have some limitations. The sample size of the study was relatively small, and some patients were excluded from analysis due to incomplete follow-up data. Additionally, the study focused only on MV sensor-driven pacing and therefore the results may not be generalized to other types of rate-responsive pacing. Despite the modest sample size, our findings suggest that in heart failure patients, rate-adaptive pacing can improve exercise capacity. As rate-responsive sensor technology continues to evolve towards more physiological designs, patient care may be improved in the future. Modern advanced pacemakers are capable of continuously collecting and analyzing heart rate data, and this capability should be used to improve the identification and treatment of chronotropic incompetence.
Author: Lehto, Sanni
Institution: University of Turku
Language: English
Field: Medicine
Open Access status: green
OpenAlex ID: W7030291327
Cites: 34
Cited by:
Related to: 10