Year: 1958
Type: article
Abstract: The development of the probe or transient needle method for thermal conductivity measurement is reviewed. The theory of the method, sources of error and an improved technique for recording the probetemperature rise are described. Experimental results for dry silica aerogel show good reproducibilityand agreement with guarded hot plate measurements. Results for snow show a discontinuousvariation of conductivity during test. The measured conductivity continuously decreased during tests on moist sawdust and moist clay, suggesting a loss of moisture from the specimen in the vicinity of the probe. This is verified by calculation of the moisture migration caused by the large temperature gradients at the probe surface. It is suggested that temperature gradients, and hence moisture redistribution, in probe tests may be reduced by increasing the probe radius, contrary to the present trend in probe development which is toward smaller probes.
Source: NPARC
Author: Woodside, W.
Language: English
Subfield: Building and Construction
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W7033019046