Spatially distributed sequential stimulation of paralyzed quadriceps muscles in functional electrical stimulation cycling
Year: 2024
Type: article
Abstract: Introduction: The major limitations of functional electrical stimulation (FES) are the low power output and the rapid onset of muscle fatigue. In isometric studies, spatially distributed sequential stimulation (SDSS) was shown to reduce muscle fatigue and augment the output power compared to the traditional single electrode setup (SES).1 Similar conclusion was reached in the study using SDSS to perform the dynamic knee extension task.2 The aim of the present study is to compare the muscle fatigue and the power produced by the paralyzed quadriceps muscles stimulated with SDSS versus SES while performing a functional cycling task. Methods: Two lower-limb motor-complete spinal cord injured (SCI) subjects participated in this case study, each in two sessions separated by 48 h. Subjects were seated in a modified recumbent tricycle with the legs secured to the custom-built cycling ergometer equipped with force-torque measuring pedals (ICS_RM, Sensix, France) synchronized with the MotiMove stimulator.3 Stimulation was delivered to the quadriceps muscles through four 5 × 5 cm electrodes acting as cathodes and one 9 × 5 cm anode. During SES all four cathodes were connected to the same stimulation channel, and for SDSS an anti-fatigue unit (3F-Fit Fabricando Faber, Serbia) was used. The stimulation parameters were: 400 μs, 70 mA and 48 Hz (12 Hz per electrode for SDSS). Each session began with a 3-min warm-up phase followed by a 3-min stimulation phase. The motor was turning the legs at 50 rpm during both phases. The type of stimulation used in the first phase was chosen randomly. After a 15-min pause, the second warm-up and stimulation phases were performed (Figure 1). In the second session, the order of stimulation phases was switched. Prior to each session, the stimulation pattern was determined by measuring the muscle activation delay and the force profile (difference between the forces produced during active and passive cycling). The mean power during the first (Pf) and last (Pl) 30 s of each stimulation phase, as well as the total mean power (Pm) were calculated. The fatigue was assessed using the fatigue index: PFI = (Pf – Pl)/Pf*100%. Results: In both subjects, SDSS produced more than two times larger total power compared to SES. The fatigue produced by SDSS compared to SES was higher for Subject 2 but lower for Subject 1. The results are presented in Table 1. Discussion and Conclusion: SDSS produced similar fatigue with more power compared to SES which is in concordance with the previous isometric and isokinetic studies in subjects with no voluntary control in stimulated muscles. The study will be conducted with more subjects to further assess the fatigue-reducing ability of SDSS applied to FES cycling.
Language: English
Topic: Spinal Cord Injury Research
Subfield: Clinical Neurology
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7034289580
