Towards the Development of a 3D ex Vivo Platform for the Evaluation of Micro-Damage, Strain Fields and Mechanical Properties in Trabecular Bone
Year: 2022
Type: dissertation
Abstract: Osteoporosis is a pathology affecting bone mineral density. Lack of symptoms makes it hard to diagnose the patients before bone fracture. Studies aiming at understanding bone biomechanics and remodeling are developed to better understand the disease. Different approaches are used to measure the mechanical properties and behavior of bone samples. One of them consists of mechanical loading of bone samples combined with medical imaging techniques (Xray microCT) to investigate the internal structures at a microscopic level. Microdamage volume and strain patterns can be computed using post imaging algorithms. This project shows two experimental studies aimed to develop an ex vivo platform to study trabecular bone samples components in 3D. A first study aimed to investigate the potential of deep learning for the segmentation of bone microdamage in trabecular bone. Six trabecular bovine bone cylinders underwent compression until ultimate stress and were subsequently imaged with a microCT at a resolution of 1.95 um. Two of these samples (samples 1 and 2) were then stained using barium sulfate (BaSO4) and imaged again. The unstained samples (samples 3-6) were used to train two neural networks, YOLOv4 to detect regions with microdamage further combined with Unet to segment the microdamage at the pixel level in the detected regions. Four different versions of YOLOv4 model were compared using the average Intersection over Union (IoU) and the mean average precision (mAP). The performance of Unet was also measured using two segmentation metrics, the Dice Score and the Intersection over Union (IoU). A qualitative comparison was finally done between the deep learning and the contrast agent approaches. Among the four versions of YOLOv4, the YOLOv4p5 model resulted in the best performance with an average IoU of 45,32% and 51,12% and a mAP of 28.79% and 46.22%, respectively for samples 1 and 2. The segmentation performance of Unet provided better IoU and DICE score on sample 2 compared to sample 1. The poorer performance of the test on sample 1 could be explained by its poorer contrast to noise ratio (CNR). Indeed, sample 1 resulted in a CNR of 7,96, which was worse than the average CNR in the training samples, while sample 2 resulted in a CNR of 10,08. The qualitative comparison between the contrast agent and the deep learning segmentation showed that different regions were segmented by the two techniques. Deep learning is segmenting the region inside the cracks while the contrast agent segments the region around it or even regions with no visible damage. A second study investigated the relationship between 3D strain maps measured by digital volume correlation (DVC) and micro-cracks localization. The complementary study also tested the deep learning models for microcracks segmentation from the first study. One trabecular bone sample was extracted from a bovine tail vertebra. It was then deformed at a quasi-static rate in multiple increments using the Deben in situ testing system inside the microCT scanner. The sample was deformed at 6% and then 10% strain or until it approached the ultimate stress (zero slope). The sample was imaged at a resolution of 2.09 um before the first loading and after every loading increment. Afterwards, the YOLOv4p5 neural network, which was trained in the first study, was applied to the volume imaged after the second deformation. The dataset was then downsampled by a factor of four to process with a DVC algorithm. In this second study, the detection of microdamage using deep learning did not provide good results. This could be explained by the dataset having a CNR much lower (1.8) than the CNR of the dataset used in the first study to train the neural network (range from 7.96 to 10.08). This strengthened the result from the first study, where training images should be diversified during training to avoid overfitting. Regions of high displacements measured by the DVC algorithm were correlated to regions of damage along the z-axis (parallel to the loading axis). However, for images in the XY plane, visualization was not precise enough to colocalize microdamage with regions of high strain. This project allowed to develop an ex vivo experimental procedure for the evaluation of micro-damage in 3D in trabecular bone. It showed the feasibility of using deep learning segmentation to detect and segment microdamage in trabecular bone samples using high-resolution Xray microCT images. Even though the deep learning model discussed in this work was not optimal, the development of a more diverse dataset with improvement in the current neural networks could make it more performant and relevant for future work. Also, correlation between region of microcracks and region of high strain along the loading axis, using DVC and an in situ compression system, showed the importance of including DVC to have a better understanding of fracture mechanics. This project opens avenues for future future studies using the in situ Deben system inside the microCT scanner to simultaneously study mechanical properties, D strain patterns, and microdamage in 3D. This knowledge is essential for the development of new diagnosis techniques for bone pathologies, such as osteoporosis.
Author: Caron, Rodrigue
Institution: Polytechnique Montréal
Language: French
Subfield: Orthopedics and Sports Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7034324360
