Year: 2014
Type: dissertation
Study design: Observational Study
Abstract: Introduction \nThe number of cases of glaucoma is predicted to increase considerably over the \nnext few decades. The current reference standard method used to distinguish \nbetween primary open angle and primary angle closure glaucoma is gonioscopy, \nbut there is a lack of evidence on anterior chamber angle (ACA) assessment \nmethods outside Asia. Optometrists who show competence at gonioscopy are well \nplaced to play an important future role in glaucoma care provision in the UK. \nAims: \n To investigate the impact of the NICE guideline on glaucoma on the clinical \npractice of optometrists. \n To investigate the ability of optometrists and other healthcare professionals \n(HCPs) at gonioscopy. \n To assess the intra-observer repeatability and agreement between \ngonioscopy, van Herick method and anterior segment Optical Coherence \nTomography (AS-OCT). \nMethods \nOptometrists were invited to complete an online questionnaire investigating clinical \npractice before and after the introduction of the NICE guideline. Gonioscopy \nfindings for optometrists and other HCPs were compared to those of a consultant \nophthalmologist. Sensitivity and specificity were calculated, weighted kappa (κw) \nwas used to assess inter-observer repeatability. \nGonioscopy, van Herick method and AS-OCT were performed on two occasions. \nSensitivity and specificity of van Herick method and AS-OCT were calculated, using \ngonioscopy as the reference standard. Kappa (κ) was used to measure the intraobserver \nrepeatability. Results \nA significant increase in the use of applanation tonometry (p < 0.01) but no \nsignificant change in gonioscopy usage (p=0.47) was found after the introduction of \nthe NICE guideline. Sensitivity and specificity values for HCPs’ gonioscopy findings \ncompared to a consultant ophthalmologist were good: 92% and 92% respectively. \nThe repeatability of gonioscopy was fair κ=0.29, while that of the van Herick \nmethod (κ=0.54) and AS-OCT (κ=0.47) were better. The van Herick method showed \ngood sensitivity (visit 1: 82%, visit 2: 75%) and very good specificity (visit 1: 88%, \nvisit 2: 95%). The sensitivity of AS-OCT was fair (visit 1: 46%, visit 2: 25%), specificity \nwas high (visit 1: 87%. visit 2: 89%). \nDiscussion \nIn this thesis new evidence is presented comparing ACA assessment tests. There \nhas been no change in gonioscopy practice since the guideline on glaucoma was \nissued. Optometrists along with other HCPs, are able to perform gonioscopy \naccurately and competently. The van Herick method and AS-OCT have better \nrepeatability than gonioscopy. The van Herick method showed good agreement \nwith gonioscopy but AS-OCT agreement with gonioscopy was less. The van Herick \nmethod would therefore appear to be a more useful test than AS-OCT for \noptometrists assessing patients at risk of glaucoma.
Author: Campbell, P
Institution: London South Bank University
Language: English
Subfield: Ophthalmology
Field: Medicine
Domain: Health Sciences
Keywords: gonioscopy, optometrists, primary open-angle glaucoma, primary angle-closure glaucoma, anterior segment optical coherence tomography, NICE guidelines, applanation tonometry, intraobserver repeatability, interobserver agreement, glaucoma diagnosis, clinical practice change, glaucoma screening
Open Access status: green
Funder: London South Bank University
OpenAlex ID: W7036886337
