Development of a Multibody Model for Quantification of Muscle Forces at Upper Limb as a Design Tool for Exoskeleton Synthesis
Year: 2022
Type: dissertation
Abstract: Assistive exoskeletons are emerging as a promising solution to provide continuous support for people affected by a diagnosis that impairs arm movements. However, functionality, safety and acceptance of these devices could be improved with a sizing based on the user's anatomy and physiology. In this context, the main objective of this research is to develop a design tool to validate, through simulation, the performance of an exoskeleton based on the quantification of muscle forces. The developed tool is applied to the movement of elbow flexion-extension (E.FE) as a benchmark-case and achieved through three steps. Firstly, a musculoskeletal multibody system of the upper limb was developed. This was achieved by integrating the four main muscles responsible for E.FE to an existing osteoarticular model. The muscles were modeled with a via-points method. The proposed model was then validated by comparing the musculo-tendinous lengths and muscle moment-arms with reference values from the literature. The relative root mean square error (rRMSE) for musculo-tendinous lengths was below 2.3 % for all muscles. The rRMSE for muscle moment arms reached respectively 14.5 % and 21.4 % for the brachialis and the triceps brachii. This high error is explained by the absence of wrapping objects in the proposed model and was only observed when the elbow is fully flexed or extended. The rRMSE on muscle moment arms for the other muscles was below 7.0 %. Secondly, the newly developed musculoskeletal model was used to quantify the muscle forces with a non-electromyography-based method. This was done with three different cost functions, namely Crowninshield, Forster, and Wen, by formulating the optimization process as an optimal control problem. The quantified muscles forces differed depending on the cost function used. Crowninshield cost function resulted in the lowest muscle forces overall while Forster and Wen were higher since they both include muscle co-contraction in their formulation. The rRMSE between the E.FE torque from inverse dynamics and the E.FE torque computed from muscle forces was below 5 % for the E.FE movement. The rRMSE was higher during functional tasks but stayed below 10 %. Thirdly, an exoskeleton was integrated to the musculoskeletal model to validate its performance through simulation. The exoskeleton was able to compensate for 80 % of the user's E.FE torque produced by the muscles. However, the reduction of the joint torque did not translate into a reduction of the actual muscle forces. Indeed, the quantified muscle forces showed an increase with the exoskeleton. This increase in the quantified muscle forces is most likely happening to compensate for the spurious forces or torques introduced by the exoskeleton's misalignment at the elbow joint. To conclude, this research introduced a new musculoskeletal model of the upper limb for muscle forces quantification that can be used as a validation tool for exoskeleton synthesis. This approach is important as it helps to rapidly identify weaknesses in the exoskeleton architecture. Future work should focus on integrating shoulder and forearm muscles to the model so it can be used on a wider range of upper limb movements and exoskeleton joints.
Author: Gaudet, Guillaume
Institution: Université de Montréal
Language: French
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W7037173119