Work

Development of HPLC-FLR method for quantification of total trisulfide in biopharmaceuticals

Year: 2020
Type: dissertation
Abstract: Background: Biopharmaceuticals represent a significant portion of the pharmaceutical market today. Drug product heterogeneity is common in biopharmaceuticals and is often introduced in manufacturing processes of biopharmaceuticals, where conditions may arise in the cell culture which leads to the formation of trisulfides. This protein modification must be controlled to maintain biosimilarity, safety, and efficacy of biosimilar drugs. Therefore, the need for adequate analytical methods for the quantification of trisulfides in biopharmaceuticals is evident. A specific method for detection and quantitation of sulfane sulfur in biological samples holds the promise of applicability of trisulfide quantification in biopharmaceuticals. \nObjective: To develop and optimize an HPLC-FLR method for quantification of total trisulfides in biopharmaceutical proteins utilizing design of experiments. \nMethod: Implementation of a sulfite method for sulfane sulfur detection and quantitation in biological samples to trisulfides in monoclonal antibodies was perfomed by optimizing the reaction condition to convert sulfane sulfur atom in trisulfides into thiosulfate. In addition, fit-for-purpose qualification was performed for monoclonal antibodies in support of the analytical method. \nResults: Reverse phased HPLC-FLR method with monobromobimane derivatization was developed and optimized through experimental design. The method was used to analyze reference protein samples from manufacturing batches and reference medicinal products for trisulfides. Fit-for-purpose qualification was performed for Alvotech‘s monoclonal antibodies and was determined successful. \nConclusion: An analytical method was successfully developed for monoclonal antibodies and fit-for-purpose qualification performed. The method was found specific, accurate, precise and linear with some limitations. Further development is needed with necessary enhancements aimed towards the addition of an approach for protein removal to the procedure and adjustments to chromatographic conditions for sufficient separation. No significant results were acquired for sample stability due to faults in HPLC system. Repeat of fit-for-purpose qualification is needed on certain parameters to ensure the quality of the method.
Source: Skemman
Author: Daníel Ómar Guðmundsson
Language: English
Subfield: Immunology
Open Access status: green
OpenAlex ID: W7046582063
Cites: 79
Cited by:
Related to: 10