Year: 2025
Type: dissertation
Abstract: Paediatric brain tumours are a severe type of diseases with treatment plans varying by diagnosis, which is typically determined by radiological imaging. Recent deep learning projects perform diagnosis classification using a single 3D magnetic resonance imaging sequence type, or fusing 2D sequences with improved performance. This thesis aims to investigate the possibility of diagnosis classification as well as the related tumour location classification using 3D MRI deep learning models trained on either a single, or multiple distinct 3D MRI sequence types. In this project, 243 pairs of T1W-GD and T2W MRI sequences of patients with paediatric brain tumours were analysed. Two classification tasks were considered: braintumour diagnosis classification (classes glioma, ependymoma and medulloblastoma) and tumour location classification (classes infratentorial and supratentorial). Three models were considered; a (vision transformer) Swin UNETR architecture trained by [1] named BrainSegFounder connected to a dense neural network, the ResNet (2+1)D and the ResNetMixed from [2] (both convolutional neural networks). The models utilized either early or intermediate fusion of sequences. The models were evaluated with various metrics: class-wise precision, class-wise recall, overall accuracy, balanced accuracy and balanced ROC-AUC. Models trained on single sequences and multiple sequences respectively were statistically compared using Wilcoxon signed rank tests on the predicted probability of the true class of each observation across models. For diagnosis classification, overall classification performance was poor compared to random chance. The models were generally able to achieve high precision and recall values for glioma, and very low values for ependymoma and medulloblastoma. No model achieved balanced accuracy above 0.5, and the balanced ROC-AUC values were in the range [0.5, 0.66]. One model achieved significantly better true class prediction probabilities when trained on fused T1W-GD and T2W sequences as compared to T1W-GD sequences, but classifications were still poor by both models. The poor performance was investigated, and deemed to likely be caused by over-fitting as a consequence of the limited training data. For the tumour location classification task, the models were able to achieve predictions marginally better than random chance. Recall values were larger than the class proportions, and balanced ROC-AUC values were in the range [0.7, 0.82]. No model trained on paired T1W-GD and T2W sequences was significantly better than corresponding single sequence models. The ResNet (2+1)D model achieved balanced accuracies 0.63, 0.59, 0.68 when trained on T1W-GD, T2W, and fused T1W-GD and T2W sequences respectively. The ResNet Mixed model achieved balanced accuracies 0.8, 0.68, 0.66 when trained on T1W-GD, T2W, and fused T1W-GD and T2W sequences respectively.
Source: DiVA (Linkoping University)
Author: Jorstedt, Simon
Institution: Linköping University
Language: English
Subfield: Computer Vision and Pattern Recognition
Field: Computer Science
Domain: Physical Sciences
Open Access status: green
Funder: Linköpings Universitet
OpenAlex ID: W7048941637
