Work

Agentes de contraste basados en lantánidos para la obtención de bioimágenes mediante técnicas de resonancia magnética a alto campo y en modo dual T1-T2

Year: 2024
Type: dissertation
Abstract: Magnetic Resonance Imaging (MRI) allows the visualization of organs and tissues for medical diagnosis. This technique is non-invasive, does not require the use of radioactive agents or high-energy electromagnetic waves, and has a high spatial resolution and a great image depth. Despite these advantages, in order to increase the contrast in these images between the region of interest and its surroundings, it is often necessary to use contrast agents (CAs), which are composed of magnetically active substances that shorten T1 and T2 proton relaxation times. Although MRI is well established in clinics, several modifications of this technique are being currently addressed with the aim of improving diagnostic reliability. In particular, high-field MRI and T1-T2 dual mode MRI have been proposed. The first one improves image resolution by using higher magnetic fields than those involved in conventional scanners (? 3 T). T1-T2 dual mode MRI involves recording bright and dark images simultaneously. By so doing, cross-validation of both types of images can be carried out, so that false positives can be excluded, and complementary information can be also obtained. Both advantages allow to increase diagnostic sensitivity and accuracy. Unfortunately, the conventional CAs used in clinics are not suitable for these novel techniques, for which, it is imperative to develop new contrast agents. For the high-field MRI technique, several alternatives have been considered. The most promising candidates are compounds based on Dy3+, since this ion has a very high magnetic moment (10.6 ?B), which leads to high transverse relaxivity values. For T1-T2 dual mode MRI, compounds based on Dy3+ ions as T2 component are equally interesting, and as T1 component, Gd3+ ions are usually used, which have a high spin angular momentum (7/2) that allows high values of longitudinal relaxivity. Different CAs have been reported in the literature, both for high-field MRI and T1-T2 dual mode MRI, consisting of fluoride-based nanoparticles containing Dy3+ and Gd3+. The main drawback of these fluoride-based nanoparticles is their solubility in aqueous media, which result in the release of potentially toxic fluoride ions. Finally, an increasing activity can be detected in literature regarding with the development of multimodal bioimaging probes, which can be used for two or more imaging techniques that allow to obtain complementary information thus improving diagnosis accuracy. Among the different possible combinations, MRI and luminescence have been widely studied. This combination of techniques is very useful for medical diagnosis since luminescent imaging gives information on pathologies at the cellular or subcellular level due to its high sensitivity, which is complementary to the anatomical information provided by MRI technique. For the former technique, working in the near-infrared (NIR) region is advantageous because this type of radiation is not harmful for biological specimens and has a high penetration deep. For multimodal bioimaging, the development of single probes that wok properly for all involved techniques would reduce undesired effects and would be more comfortable for the patient. So far, most of the probes reported in literature for MRI and NIR luminescent bioimaging are also fluoridebased nanoparticles, whose drawbacks for in vivo applications has been already discussed. The main objectives of this doctoral thesis are the development of chemically stable contrast agents for high-field single-modal MRI, for T1-T2 dual mode MRI and for multimodal imaging by using high-field MRI and near-infrared luminescent imaging.
Language: English
Open Access status: green
OpenAlex ID: W7054649865
Cites: 153
Cited by:
Related to: 10