Evaluating energy and indoor air quality potential impact of spray foam: a case study of robotic application
Year: 2023
Type: dissertation
Abstract: Homes in the UK require transformational retrofit to meet Net Zero legislation. \nSelecting the right insulation balances multiple, often clashing, performance criteria: \nenergy savings, capital cost, thermal comfort, installation disruption, heritage impact \nand indoor air quality. There is a lack of evidence in balancing trade-offs between \nenergy, heritage and indoor air quality impact when comparing insulation products. \nThis thesis converged data from different disciplines and showed the retrofit potential, \nkey barriers and enablers of insulating millions uninsulated floors in the UK. In \nunderfloor voids with limited space polyurethane spray foam applied with robots \noffers better insulating potential compared to conventional products with the same \nthickness, however more scientific evidence was needed on off-gassing emissions. \nTo measure spray foam emissions, heritage science techniques were adopted to \ndevelop a novel method. The method could be applied in built environment case \nstudies to measure volatile organic compounds (VOC) from polyurethane products. \nThe VOC emissions during spraying were assessed for a majority of spray foam product \navailable on the open market. The original data provided evidence for generating a \nnew hypothesis for why 1,2-dichloropropane (1,2-DCP) was found in spray foams. The \ndata suggests 1,2-DCP may have been part of some of the raw materials contrary to \nthe existing hypothesis from 2003 suggesting it was a result of flame retardants \ndegradation. This is relevant as 1,2-DCP was re-classified as Class 1 carcinogen in 2014. \nFurthermore, ventilation strategies and their effectiveness as a mitigation measure for \nreducing VOCs were evaluated. Spray foam VOC concentrations were first measured \nin controlled conditions. Experimental data revealed that VOC concentrations are \nsignificantly lower next to sprayers when robots and robust ventilation are deployed. \nThe findings were validated in a case study where long-term VOC concentrations were \nmeasured for a period of up to 2 months after retrofit. The majority of VOC \nconcentrations were not detected indoors post-installation with the exception of \nflame retardants.
Author: Naldzhiev, Dzhordzhio
Institution: University College London
Language: English
Subfield: Building and Construction
Field: Engineering
Domain: Physical Sciences
SDG: Climate action
Open Access status: green
OpenAlex ID: W7056542621