LC-MSMS- og GC-MS(MS)-metoder for analyse av anabole steroider i urin - En litteraturstudie
Year: 2020
Type: dissertation
Abstract: Articles including methods for analyzing anabolic steroids in urine using LC-MSMS and GC-MS(MS) have been studied. Sources for the literature study were obtained from Google Scholar, PUBMED and ORIA. Relevant articles are: Jeon B.W et al. (2011), Pozo O.J et al. (2007), Rzeppa S. et al. (2015), Balcells G. et al. (2015), Marcos J. et al. (2002), Cha E. et al. (2015) and Kala S.V et al. (2007). Each of these articles present the analysis of 8 – 20 steroids. The methods of sample preparation, chromatographic separation and mass spectrometric detection of anabolic steroids were evaluated and compared with consideration to the method’s performance and given validation results, such as LOD and precision. The LC-MSMS and GC-MSMS methods described by Cha E. et al. (2015) analyzed 20 anabolic steroids (boldenone, 5β-androst-1-ene-17β-ol-3-one, 1α-methyl-5α-androstane-3α-ol-17-one, methandienone, epimethendiol, 4-dehydrochlormethyltestosterone, methenolone, 1-methylene-5α-androstane-3α-ol-17-one, nandrolone, 19-norandrosterone, 19-norethiocholanolone, oxandrolone, 17epi-oxandrolone, oxymesterone, oxymetholone, 17α-methyl-5α-androstane-3α,17β-diol, stanozolol, 3-OH stanozolol, trenbolone and 17α-trenbolone). Because of their low LOD ≤ 2,5 ng/mL for 15 of 20 steroids, these methods are recommended. The LC-MSMS methods described by Rzeppa S. et al. (2015) analyzed 9 anabolic steroids (boldenone, 2α-methyl-5α-androstane-3α-ol-17-one, 1α-methyl-5α-androstane-3α-ol-17-one, methenolone, 1-methylene-5α-androstane-3α-ol-17-one, 19-norandrosterone, 19-norethiocholanolone, trenbolone and 17α-trenbolone). The method analyzed sulphate conjugate, which made it stand out. Sulphate conjugates simplified sample preparation, ionization of steroids and may also provide extended window of detection. This, as well as its low LOD ≤ 1,0 ng/mL and reproducibility ≤ 15%, makes the method recommended. In addition, it is written in the article that it is expected that several steroids can be analyzed with similar validation results. This provides a good basis for further development of this method.
Source: NVA (Nasjonalt vitenarkiv)
Authors: Anita Andås Nygård, Ingrid Elise Berge Jenssen, Målfrid Roset
Institution: Norwegian University of Science and Technology
Language: English
Topic: Doping in Sports
Subfield: Sociology and Political Science
Field: Social Sciences
Domain: Social Sciences
Keywords: anabolic steroids, urine analysis, LC-MS/MS, GC-MS/MS, method comparison, sample preparation, chromatographic separation, mass spectrometry detection, method validation, detection limit, precision, doping control, performance-enhancing drugs, nandrolone, oxandrolone, stanozolol, trenbolone, boldenone
Open Access status: green
OpenAlex ID: W7057723197