Abstract: Novel Sampling Trajectories in Echo-Planar-Imaging Echo-Planar-Imaging (EPI) is the fastest way to acquire images in Magnetic Resonance Imaging (MRI) [1]. It enables whole brain image acquisition in 0.5 to 5 seconds. Due to these short acquisition times, EPI is especially employed with applications like diffusion MRI that are sensitive to motion [2]. Furthermore, EPI is also used to capture dynamic processes like functional MRI [3]. However, EPI comes with certain disadvantages like distortions from static magnetic field inhomogeneities and signal dropout and blurring through relaxation effects [4]. EPI also produces noise levels of up to 130 dB [5] because the fast gradient switching required causes mechanical vibration of the gradient coil. This noise is detrimental to functional studies where it is critical to hear and understand acoustic stimulations like music or commands from the operator for adequate brain activity measurements [6, 7]. The first part of this work investigates how to decrease acoustic noise for EPI based sequences. In the second part, methods are developed to reduce distortions in EPI acquisitions whilst maintaining the same acquisition speed. The novel method reduces acoustic noise via prolonging the blipped Phase-Encoding (PE) and multiband encoding gradients. Additionally, data points are sampled throughout the whole Readout (RO) meaning k-space is acquired in a non-Cartesian way. However, the deviations from a Cartesian trajectory are small enough so that Cartesian reconstruction methods can still be employed. The reconstruction time is thereby kept in a clinical acceptable time frame of less than one second. The novel method is furthermore combined with two well-known techniques to reduce acoustic noise. Firstly, a sinusoidal RO gradient is used which also has the advantage of tuning the sequence frequency spectrum to a local minimum of the gradient system [8]. Secondly, RO segmentation is employed to reduce gradient amplitude and slew-rate [9, 10]. Through the combination of these methods the acoustic noise can be decreased by 20 dB. Distortions can be reduced by using RO segmentation [11]. This comes at a cost of increased measurement time. To reduce measurement time, a novel way of under-sampling k-space which considers the variation between segments along the RO direction is introduced. This enables a measurement time reduction by roughly a factor of 2 with no impact on image quality. Interleaved EPI is another way to reduce distortions [12]. In interleaved EPI, k-space is acquired in multiple shots along the PE direction. This work also demonstrates an additional novel technique for under-sampling k-space in 3D EPI while interleaving along both PE directions. This enables the application of Compressed Sensing (CS) [13] in EPI for the first time. For anatomical imaging typically gradient echo sequences with undersampling factors of up to 12 are used. In comparison, this novel method (combining EPI with CS), yields acceleration factors of up to 131.6 at a comparable image quality.
Author: Liebig, Patrick
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7058782384